background image

Configuration Mode: Adjustment of basic parameters

Remark: If you have ordered the A-100CGK with metal case and 4 octaves
keyboard, and want to use it in combination with the A-100 system it is not necessary
to call up the configuration mode as the factory settings are chosen exactly for this
application – unless you want to change the transpose type.

Additional 

basic parameters

 are adjusted in a special configuration mode and

include parameters that are normally fixed, i.e. they are not changed during the play.
The configuration mode is selected if the up or down button is held down during
power on. The configuration mode is indicated by 

CoF

 in the display. In addition all

LEDs light up. To adjust a parameter the corresponding menu button has to be
operated. Then the corresponding LED turns off while all other LEDs remain on (i.e.
inverse LED display compared to the normal mode). The up/down buttons are used
to increase/decrease the value of the currently selected parameter. To exit a menu
another menu button has to be pressed. The four menu buttons are assigned to
these basic parameters:

MODE

This configuration menu is used to adjust the number of octaves of the keyboard. For
the standard version with metal case and 4 octaves keyboard the value has to be set
to 

4

 (factory setting). For the OEM version the corresponding octave length has to be

chosen: 2, 3, 4 or 5. This adjustment is necessary to select the correct note offset
and to limit the transpose range for different keyboards.

The factory setting is 

4

.

TRANSP.

This configuration menu is used to select the type of transpose:

 

Oct

transpose in octave intervals (i.e. 12 semitones)

 

SEM

transpose in semitone intervals

The factory setting is 

Oct

.

RETRIG.

This configuration menu is used to select the polarity of the gate signal:

 

POS

positive gate polarity

 

NEG

 

negative gate polarity

If positive polarity is chosen the gate socket outputs a positive voltage when a key is
pressed. The gate voltage turns to 0V when no key is operated. If negative polarity is
selected the behaviour is the opposite, i.e. 0V when a key is operated and a positive
voltage when no key is pressed. The A-100 and most of other synthesizers or
systems work with positive gate polarity. Some synthesizers or systems (e.g. Moog)
require a negative polarity. If the device connected to the A-100CGK works opposite
(i.e. the sound disappears when a key is pressed and is triggered if a key is released)
the gate polarity has to be changed.

In addition the gate voltage depends upon the internal jumper setting (+5V, supply
voltage or S-Trig). As the case has to be opened for this the procedure should be
carried out by a specialized company only. The jumper for the gate voltage is located
just behind the gate socket. It can be installed in two different positions:

 

towards the 9 pin sub-D socket

gate voltage = supply voltage (e.g. +9V)

 

towards the transistor

gate voltage = +5V

Содержание A-100CGK

Страница 1: ...DOEPFER CV Gate Keyboard CV Gate Keyboard CV Gate Keyboard CV Gate Keyboard A 100CGK A 100CGK A 100CGK A 100CGK User s Guide www doepfer com...

Страница 2: ...ronment nor near inflammables No liquids or conducting materials must get into the instrument If this should happen the instrument must be disconnected from power immediately and be examined cleaned a...

Страница 3: ...the Fatar website www fatar com All Fatar keybeds with up to 5 octaves can be combined with the A 100CGK OEM kit longer keybed are not possible These are the most important features of the A 100CGK re...

Страница 4: ...de is selected if the up or down button is held down during power on o keybed type 2 3 4 5 octaves necessary for transpose and offset options has to be set to 4 for the ready built version o transpose...

Страница 5: ...as well as a minimum current of 250mA The correct polarity of the DC voltage connector is outside ring GND inside lead 7 12V An external power supply of high quality and safety should be used The A 10...

Страница 6: ...A 170 A 171 to obtain a slowly increasing or decreasing control voltage that can be used to control other modules e g the frequency of a VCLFO A 147 or the amplification of a VCA A 130 131 132 to obt...

Страница 7: ...right panning A 134 or to control any other voltage controlled parameter of an A 100 module CV3 This 3 5 mm jack socket is the control voltage output of the A 100CGK that is controlled by the after t...

Страница 8: ...polarity or does not work Controls Display 3 digit LED display Six buttons with corresponding LEDs four to select a menu MODE TRANSP RETRIG HOLD two as up down buttons UP DOWN A menu is activated by...

Страница 9: ...ctaves keyboard 0 to 12 same as described above 5 octaves keyboard no transposition possible The reason for the different transpose ranges is the voltage range of CV1 0 5V This corresponds to 5 octave...

Страница 10: ...has to be chosen 2 3 4 or 5 This adjustment is necessary to select the correct note offset and to limit the transpose range for different keyboards The factory setting is 4 TRANSP This configuration m...

Страница 11: ...adjusted parameters in the configuration mode are valid i e number of octaves of the keyboard transpose type and gate polarity Extent of delivery The A 100CGK delivery contains the following parts 1...

Страница 12: ...008 by Doepfer Musikelektronik GmbH Geigerstr 13 82166 Graefelfing Germany Phone 49 89 89809510 Fax 49 89 89809511 Web Site www doepfer de Email sales doepfer de Doepfer Musikelektronik www doepfer co...

Отзывы: