BG80 USE AND MAINTENANCE BOOKLET
Rev.1 of 23/04/2013 of BG80 uk agg2013 Page 22 of 40
The wooden chocks must be removed before handling the machine, and inserted into the packaging to ensure
stability during shipping.
Lift the machine, taking care not to unbalance the load during the manoeuvre.
6
6
.
.
4
4
.
.
RECEIPT
Upon receiving the Machine, check that the delivery corresponds to the order specifications and that the
package and its contents have not been damaged during transport.
The packaging should be removed as follows:
⇒
Cut the packaging from around the sides (if using cutters make sure not to cut directly onto the machine so
as not to damage the parts underneath the packaging)
⇒
Remove the packaging from around the sides.
If you notice damage, faults or missing contents, notify the following centre immediately:
DODA Assistance Centre Tel. ++390376410043 Fax ++390376410032.
6
6
.
.
5
5
.
.
STORAGE
If the product needs to be put into storage for a period greater than 2 months, observe the following
procedures:
⇒
Protect the shafts and centering mechanisms using a film of lubricant and/or a protective anti-corrosion
liquid;
⇒
Store in a dry place at a temperature of between -5°C e +30°C;
⇒
Protect the packages from dirt, dust and humidity;
⇒
Do not stack the pieces one on top of another;
⇒
Do not walk on the package, and do not place items on top of it;
⇒
Do not place the package near passageways;
⇒
If possible, position chocks of wood between the package and the pavement.
NOTE: The performance of the rotating seals is negatively impacted if the product is stored for extended
periods of more than 6 months. Periodic checks should be carried out by rotating the internal gears by
hand to rotate the inlet shaft. The gaskets should be replaced if necessary at the time of commissioning
the machine.
7
7
ORDINARY / EXTRAORDINARY MAINTENANCE
Check all screws and bolts on the mixer, the frame and the parts after the first 2 operating hours and again after
100 operating hours (or else after 1 month of operating!).
Check the fixing plugs on the assembly frame of the mixer and if necessary tighten them further.
MOMENT OF TORSION OF THE SPRINGS IN Nm
Screw
M8
M10
M12
M16
M20
M24
Category A2/ A4-70
16
32
56
135
280
450
Category 8.8 galvanised
20
41
70
170
330
570
Category A2/ A4 - 80
Plug M12-15/110 A4
50
It is possible that condensation may form on the terminal strip of the explosion-proof motors; for this
reason, the mixer should be stopped at regular intervals (at least once a month) and any condensation
water should be removed from the terminal strip using an appropriate absorbent cloth.