12
7360/7363 Installation and Programming Guide | Digital Monitoring Products, Inc.
Keypad Diagnostics
LCD Segment Test
At diagnostics startup the keyboard is backlit at maximum brightness and all the icons
flash on and then off as a group. The keypad alternates between these two states for
approximately two minutes. Press the Back Arrow to return to the Panic Keys option. Press
CMD at any time to continue to the next test.
Test Individual Keys and Card Read
When a top row select key is pressed, the corresponding Cancel, Bypass, Extend, or
Verify option is displayed. When keys 0-9 are pressed, the number of the selected key is
displayed in the 3-digit display. If a proximity credential is presented during the key test,
the keypad beeps once for a successful read.
Exiting the Installer Options
Press the CMD to end Installer Options. Press the Back Arrow key to return to the LCD
Segments test.
Содержание Thinline 7360
Страница 2: ......
Страница 4: ......
Страница 23: ...Digital Monitoring Products Inc 7360 7363 Installation and Programming Guide 19...
Страница 24: ...LT 0953 1 03 20175 2020 Digital Monitoring Products Inc...