Страница 1: ...Installation Guide SCS 1R Security Control Receiver DMP Receiver Help Line Technical Service 1 888 436 7832 International 1 417 831 9362 After hours receiver emergencies 1 417 831 2866...

Страница 2: ...ntrol Receiver Model SCS 1R Installation Guide 2003 2008 Digital Monitoring Products Inc Information furnished by DMP is believed to be accurate and reliable This information is subject to change with...

Страница 3: ...uit Boards 4 SCS 208 Power Cord 4 Phone Lines 4 Network Connection 4 AC Power 4 Optional Printer 4 Start up 4 Configuration 4 Model SCS 1R Security Control Receiver Description 5 SCS 1R Components Inc...

Страница 4: ...r Monitor LEDs 12 Model SCS 130 Transformer Card Description 13 Installation 13 AC Power Connection 13 Three Amp Fuse 13 Model SCS 208 Power Cable Description 14 Installation 14 Model SCS 202 Convenie...

Страница 5: ...essor Messages 26 Alarm Trouble and Restore 27 Ambush 27 Opening and Closing 27 Bypass and Reset 27 Add and Delete Codes 27 Schedule Changes 27 Door Access 27 Acknowledgment of Fire Alarms and Trouble...

Страница 6: ...requires acknowledgement the ACK LED lights and the keypad begins to beep If more than one message is received the Message LED also lights You must exit programming before you can acknowledge any ala...

Страница 7: ...ransmitted to the SCS 1R by DMP Command Processor panels include Operator code number additions and deletions including the name of the person making the change Zone bypasses and resets by name and nu...

Страница 8: ...Port 2 Port 3 Port 4 Port 5 Model SCS 110 Modem Rack Supply Card UPS Brownout Input Model SCS 100 Line Card or Model SCS 101 Network Interface Card Model SCS 100 Line Card or Model SCS 101 Network Int...

Страница 9: ...bles are crossover cables When you hold the two connectors of one cable side by side the wire colors should be mirror images as shown in the diagram Network Connection When using a network interface c...

Страница 10: ...nded to include a maximum of five incoming communication lines The SCS 101 Network Interface Card allows you to connect a digital data network to the SCS 1R Receiver SCS 1R Components Included The SCS...

Страница 11: ...me pre mounted and pre wired with the power cable and ribbon cable Installing the SCS RACK Connect the SCS RACK to earth ground before making any module connections Use a minimum 14 gauge wire for gro...

Страница 12: ...s or port 7 for odd numbered ports Refer to the diagram below when configuring the ports for NET or SDLC Configuring the Line Jumpers After configuring the port jumpers set the line jumpers according...

Страница 13: ...iption The SCS 100 provides for one incoming line of digital dialer DD communication to DMP Command Processor panels Each line card includes one 10 position flat cable for processor card connection an...

Страница 14: ...on is power limited and supervised for fire communicating accounts The SCS 100 is registered with the FCC registration number CCK8GW 16197 AL N Ringer Equivalence 1 2 Phone Line Monitor The SCS 100 mo...

Страница 15: ...rk connection is power limited and supervised for fire communicating accounts Communication The SCS 101 automatically communicates UDP or TCP with DMP XR500 Series and XR2500F Command Processor panels...

Страница 16: ...d by the SCS 120 Multibus Power Supply Card and lights when there is a power problem on the SCS 110 The red LED remains lit until the power problem is corrected The alert tone on the SCS 110 Modem Pow...

Страница 17: ...backplane The green OK LED lights when the processor operates If the processor stops operating the red FAIL LED lights and the SCS 120 failure buzzer sounds Press the processor restart button to resta...

Страница 18: ...he multibus cooling fan on the lower right side of multibus rack AC Power Connection Connect 120 VAC to the SCS 1R Receiver through the SCS 130 Transformer Card The SCS 1R Receiver backplate provides...

Страница 19: ...g printer connector Connect the other ribbon cable between port 8 and the Host Computer connector Install the metal plate with the two 25 position RS 232 connectors on the SCS 1R Receiver backplate us...

Страница 20: ...nication information system options area information Programs zone information and the number and type of Security Command keypads in the system This should not be confused with System Programs that a...

Страница 21: ...ng section you want displays When the SCS 1R system is in normal mode the Select keys are used to acknowledge alarm messages Press the Select key labeled ACK or any top row Select key to acknowledge t...

Страница 22: ...ver a key is pressed If no keys are pressed and the speaker has not sounded for 30 seconds the user selected brightness level restores Set TONE Speaker Tone Set the keypad internal speaker tone At the...

Страница 23: ...o yes Zone 2 Shunt Leave this option set to NO Activate zone 3 Exit no yes Zone 3 Exit Leave this option set to NO 4 digit entry Cards no yes Entry Cards Leave this option set to NO All No yes Delay 2...

Страница 24: ...Date This selection allows you to set the correct time day and date on the SCS 1R All changes made in this selection print to the Activity Log printer The time entered here is sent to panels if the p...

Страница 25: ...key under ADD to add a new operator Press the Select key under DEL to delete an operator Press the Select key under CHG to change an operator Note Select CHG to view the current operator information...

Страница 26: ...er alphanumeric entry This key is requested by Command Processor panels in the field when using remote programming Once entered this key does not display and should never be changed Record this number...

Страница 27: ...12345 ZONE 123 FIRE Alarm Off Normal Zone Display Example After pressing the top row Select key under ZONES all off normal zone messages display similar to the one shown on the left The line number is...

Страница 28: ...omation Press any top row Select key to program Host Automation settings Press the COMMAND key to advance to the next programming section Press the Back Arrow key to return to the System Status sectio...

Страница 29: ...serial printer that is listed for Fire Protective Signaling Systems crc error check No yes CRC Error Check Press the far right Select key for YES which allows each message sent to the host to be pref...

Страница 30: ...d Kwajalein Kamchatka Dialer LINE CARD MONITOR No yes Dialer Line Card Monitor Press the far right Select key for YES to enable monitoring of all SCS 100 digital dialer line cards for any failed commu...

Страница 31: ...010 FRONT DOOR BYP Usr 015 8 33 a m 1 1 Usr 009 added to panel Usr 002 8 33 a m 1 1 Permanent schedule for Tuesday Area 1 8 35 a m Open 8 00 a m Close 5 30 p m Usr 005 1 1 Door access Dr 001 Usr 021 8...

Страница 32: ...e of the individual making the change The message prints on the Activity Log only Schedule Changes This prints in a 2 line format listing the type of schedule day of the week opening and closing time...

Страница 33: ...ight the SEL light If the light does not come on turn the unit off for five seconds and try again PAPER Light Lit In this case the SEL light cannot be lit and paper must be added Bad Printer Cable If...

Страница 34: ...hone lines NET Network is not a polled format Using NET the panel sends supervision messages when programmed and receives acknowledgments for the messages from the receiver in much the same way a dial...

Страница 35: ...ion jumpers located on the main SCS 1062 card in a row along the back of the individual port cards Set the jumpers according to the list of pin numbers in the table below For SDLC For NET Line 1 1 4 6...

Страница 36: ...When you finish configuring the port for Network communication the port should look like the port in the figure below Port 1 NET Port 2 NET F Z Y X bb aa dd cc R Q W T S U V hh ii jj P O N M L K E D C...

Страница 37: ...to reflect power cord connection SCS RACK System Enclosure Updated Rack Mounting for NRTL listed Fire Signaling applications SCS 100 Line Card Added Maximum line impedance SCS 101 Line Card Added Max...

Страница 38: ...H Host 14 35 Host Automation 23 29 Acknowledge Timeout 23 Area Format 24 Baud Rate 23 CRC Error Check 24 Dialer Line Card Monitor 25 Line Number Length 23 Printer Disable 24 Print Always 24 Retries t...

Страница 39: ...er Card 13 SCS 1R Faceplate 4 Hours from GMT 25 Included Components 5 Print Always 24 Time to Panels 25 SCS 202 Convenience Panel 14 SCS 204 Host Cable 14 SCS 208 Power Cable 14 SCS PTR Printer 4 SCS...

Страница 40: ...SCS 120 Multibus Power Card SCS 130 Transformer Card SCS 202 Convenience Panel SCS 204 Host Cable SCS 208 Power Cord SCS 1062 Main Processor Card Accessory Devices SG DPU 414 Printer with Power Suppl...