2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
2
SC Series Keypad Installation
Keypad harness wiring
Violet - Relay Normally Closed
Green/White - Wiegand Data 0
Output/Reader Harness
Data Bus/Zone Harness
Gray - Relay Common
Orange - Relay Normally Open
White - Wiegand Data 1
Zone 2 White/Red
Zone 3 White/Orange
Zone 1 White/Brown
Zone 4 High White/Yellow
Red - Keypad Main DC Power Input
Yellow - Send Data to LX-Bus
Green - Receive Data from LX-Bus
Black - Ground
Battery Backup Red/Black
Bell Switched Ground Blue
Zone 1, 2, and 3 Ground Black/White
Zone 4 Low Yellow/White
Wire
harness
entrances
Combined 4 square and 3-gang
switch box mounting holes.
Insert the reference card
between the two guide tabs
before installing the keypad.
Keypad
Reference
Card
Write the zone
descriptions
on the front of
the card
before
inserting the
card into the
keypad.
Gently twist while pulling halves
apart. Repeat at other opening.
Surface and backbox
mounting holes.
Surface and backbox
mounting holes.
Surface and backbox
mounting holes.
Keypad Mounting Template
Installing the keypad
The SC Series keypads each use the same plastic housing and
are designed to easily install on any 4 square box, 3-gang switch
box, 695 and 696 backbox, or flat surface. The Keypad Mounting
Template below shows the mounting hole location and reference
card location on the keypad base. Use this template as a guide for
mounting the keypad.
Wiring the keypad
The keypads are each supplied with one 12-wire Data Bus /Zone
harness. The 741 and 743 also include one 5-wire Output/Reader
harness. The harness connections and color codes are shown in
the keypad harness wiring diagram.
Once all the wire connections are made, mount the keypad using
appropriate size anchors and the enclosed screws.