Arming/Disarming Ademco Vista Panels
The following steps describe how to configure the communicator to arm and disarm an Ademco Vista control panel
from a schedule or remotely from the Virtual Keypad App, VirtualKeypad.com, or Remote Link™ using the remote
arming output.
1. Connect output 17 (far left pin on the 7 pin header located in the middle of the PCB) to zone 1 (Z1) on the
communicator. Connect a 1k ohm EOL resistor from zone 1 to ground (G).
2. Connect output 1 (O1) on the communicator to zone 3 (terminal 12) on the Vista control panel.
3. Begin programming by entering the installer code followed by
800
. Press
*
and
Field ?
displays.
4. Program zone 3 as an arming zone. Enter
56
and program the following:
a.
Set to Confirm?
‑ Enter
0
.
b.
Enter Zn Num.
‑ Enter
03
. Press
*
to continue.
c.
Summary Screen: Zn ZT P RC HW:RT
‑ Press
*
to continue.
d.
Zone Type
‑ Enter
77
. Press
*
to continue.
e.
Report Code 1st 01 2nd 00 10
‑ Press
*
to continue.
f.
Hardware Type
‑ Enter
0
. Press
*
to continue.
g.
Resp Time
‑ Enter
1
. Press
*
to continue.
h.
Summary Screen: Zn ZT P RC HW:RT
‑ Press
*
to continue.
i.
Program Alpha
‑ Enter
0
.
j.
Enter ZN Num
displays. Enter
00
to exit.
5. Program output 17.
Enter * or #
displays. Press
*
and
Field?
displays. Enter
79
and program the following:
a.
Enter output No
‑ Enter
17
. Press
*
to continue.
b.
Output Normally Low
‑ Enter
0
. Press
*
to continue.
c.
Enter Output No
displays. Enter
00
to exit.
6. Define output 17 actions.
Enter * or #
displays. Press
*
and
Field?
displays. Enter
80
and program the following:
a. Program output 17 to turn on when armed Stay.
Output Funct#
‑ Enter
01
. Press
*
to continue.
•
Summary Screen: 01 A E P Trig
‑ Press
*
to continue.
•
Activated by: - Enter 2
. Press
*
to continue.
•
Enter Zn Type
‑ Enter
20
. Press
*
to continue.
•
Output Action
‑ Enter
2
. Press
*
to continue.
•
Enter Output No.
‑ Enter
17
. Press
*
to continue.
•
Summary Screen: 01 A E P Trig
‑ Press
*
to continue.
b. Program output 17 to turn on when armed Away.
Output Funct#
‑ Enter
02
. Press
*
to continue.
•
Summary Screen: 02 A E P Trig
‑ Press
*
to continue.
•
Activated by:
‑ Enter
2
. Press
*
to continue.
•
Enter Zn Type
‑ Enter
21
. Press
*
to continue.
•
Output Action
‑ Enter
2
. Press
*
to continue.
•
Enter Output No.
‑ Enter
17
. Press
*
to continue.
•
Summary Screen: 02 A E P Trig
‑ Press
*
to continue.
c. Program output 17 to turn off when Disarmed.
Output Funct#
‑ Enter
03
. Press
*
to continue.
•
Summary Screen: 03 A E P Trig
‑ Press
*
to continue.
•
Activated by:
‑ Enter
2
. Press
*
to continue.
•
Enter Zn Type
‑ Enter
22
. Press
*
to continue.
•
Output Action
‑ Enter
0
. Press
*
to continue.
•
Enter Output No.
‑ Enter
17
. Press
*
to continue.
•
Summary Screen: 03 A E P Trig
‑ Press
*
to continue.
d.
Output Funct#
‑ Enter
00
. Press
*
to continue.
7.
Enter * or #
displays. Press
*
and
Field?
displays. Enter
99
to exit programming.
8. Programming the communicator.
a. Reset the communicator. Enter
6653
.
b. Press
CMD
to output options. Press any select area.
c. Program output 1 in remote arming output. Press
CMD
to
RMT ARMG OUT
. Enter
1
, then press
CMD
.
d. Press
CMD
to zone information. Press any select area and
Zone No
displays.
e. Enter
1
. Press
CMD
.
f. Enter a zone name. Press
CMD
.
g. Program zone 1 as an arming zone.
Zone Type
displays. Choose arming zone type
AR
. Press
CMD
.
h.
Area: 1------
displays. Press
CMD
.
i.
Style: TOGGLE
displays. Choose
MNT
.
j. Go to
STOP
then press and select key to save and exit programming.