Installing the Keypad

All DMP keypad housings are designed to easily install on any single–gang switch box or flat 

surface. Figure 3 shows the keypad housing base mounting hole locations.

Wiring Specifications for Keypad Bus

When planning a keypad bus installation, keep in mind the following specifications:

1. 

DMP recommends using 18 or 22–gauge, unshielded wire for all keypad and  
LX–Bus circuits. Do not use twisted pair or shielded wire for LX–Bus and keypad 
bus data circuits. To maintain auxiliary power integrity when using 22–gauge wire 
with a Model 7872 or 7873, do not exceed 225 feet. When using 18–gauge wire, do 
not exceed 500 feet. Install an additional power supply to increase the wire length 
or add devices.

2.  Maximum distance for any one circuit (length of wire) is 2,500 feet regardless of 

the wire gauge. This distance can be in the form of one long wire run or multiple 
branches with all wiring totaling no more than 2,500 feet. As wire distance from 
the panel increases, DC voltage on the wire decreases.

3.  Maximum number of devices per 2,500 feet circuit is 40. 

 

 

Note:

 Each panel allows a specific number of supervised keypads. Add additional 

keypads in the unsupervised mode. Refer to the panel Installation Guide for the 
specific number of supervised keypads allowed.

Installing the Keypad

Содержание 7872

Страница 1: ...INSTALLATION GUIDE 7800 Series Graphic Touchscreen Keypad TODAY WEDNESDAY 82 98 77 HI LO CURRENT 98 77 HI LO ...

Страница 2: ... 2017 Digital Monitoring Products Inc Information furnished by DMP is believed to be accurate and reliable This information is subject to change without notice ...

Страница 3: ...ur fully programmable Class B Style A supervised power limited protection zones and a built in proximity card reader designed to read DMP HID proximity credentials Model 7873 The Model 7873 keypad provides four fully programmable Class B Style A supervised power limited protection zones and a built in proximity card reader designed to read DMP HID proximity credentials The Model 7873 keypad also p...

Страница 4: ...a Model 7872 or 7873 do not exceed 225 feet When using 18 gauge wire do not exceed 500 feet Install an additional power supply to increase the wire length or add devices 2 Maximum distance for any one circuit length of wire is 2 500 feet regardless of the wire gauge This distance can be in the form of one long wire run or multiple branches with all wiring totaling no more than 2 500 feet As wire d...

Страница 5: ...031 for more information Also see the 710 Module Installation Sheet LT 0310 Keypad Specifications Model Normal Standby Current Alarm Current Four Zones Internal Prox Reader Wiegand Input Internal Door Strike Relay 7872 130mA 1 6mA per active zone 165mA 2mA per active zone X X 7873 130mA 1 6mA per active zone 165mA 2mA per active zone X X X X Specifications Operating Voltage 12VDC Dimensions 5 8 W ...

Страница 6: ...I Card 1386 HID ISOProx II Card 1346 HID ProxKey II Access Device Proximity Readers for 7873 keypads PP 6005B ProxPoint Plus 30mA Standby 75mA Peak MP 5365 MiniProx 20mA Standby 110mA Peak PR 5455 ProxPro II 25mA Standby 125mA Peak TL 5395 Thinline II 20mA Standby 115mA Peak Keypad Mounting 695 7800 In Wall Mount Backbox 698 7800 Plastic Keypad Wall Cover 699 7800 Keypad Deskstand with Cord Instal...

Страница 7: ... wires near the base and hold the outside edges of the keypad housing Line up the red and yellow wires with the guides on the board to inset the connector into the J5 keypad terminal See Figure 2 Note Do not remove the keypad housing to install the wiring harness 2 Observe wire colors when connecting the red yellow green and black wires to the keypad bus Connect red wire to Panel Terminal 7 Connec...

Страница 8: ...EX 4 Zone 4 Yellow White White Yellow Using the 7800 Keypad for Access Control 7873 Card Readers When a proximity credential is presented to an internal or external reader a beep tone is heard and the Power Armed LED blinks This provides both an audible and visual acknowledgment of the credential read Internal Access Control Reader The 7873 and 7872 keypads provide a built in proximity card reader...

Страница 9: ...ed White White Red Brown White White Brown Black Ground Red Keypad Power Zone 1 Zone 2 Zone 3 Zone 4 Zones 1 to 4 7872 7873 Keypads External Card Reader Green White Connect Reader Data 0 Black Ground Green Receive Data Yellow Send Data Red Keypad Power All Keypads Red Black Green Yellow Surface and Backbox Mounting Holes Keypad Back Figure 3 12 VDC Reader Wiring Using the 7800 Keypad for Access Co...

Страница 10: ... C relay draws up to 15mA of current and the contacts are rated for 1 Amp at 30VDC maximum resistive Wiring the 333 Suppressor One Model 333 Suppressor is included with the 7873 keypad If the device being controlled by the relay is connected to the N O and C wires install the suppressor on the N O and C wires If the device is connected to the N C and C wires install the 333 on N C and C wires Refe...

Страница 11: ... can provide a programmed bypass time by connecting its contact to Zone 2 white red pair on the keypad and enabling the Bypass feature See Zone 2 Bypass on page 19 for more information Door contacts may be N C or N O 1K EOL 1K EOL 1K EOL 1K EOL Green White Connect Reader Data 0 White Connect Reader Data 1 Orange N O Gray Common Violet N C Yellow White White Yellow Orange White White Orange Red Whi...

Страница 12: ... seconds after the keypad reads a card and a door strike occurs This is to allow area entry and pass under a REX PIR Additional Power Supply The maximum voltage drop between the panel and any device is 2 0VDC If the voltage at any device is less than the required level add an auxiliary power supply at the end of the circuit When the voltage is too low the devices cannot operate properly Keypad Key...

Страница 13: ...panel Depending on the operation the LED displays in red or blue as listed in the table below Color and Activity Operation Blue Steady Panel Disarmed AC Power OK Battery OK Blue Blinking Panel Disarmed AC Power OK Battery Fault No Light Panel Disarmed AC Power Fault Battery OK Red Steady Panel Armed AC Power OK Battery OK Red Blue Alternate Panel Armed AC Power OK Battery Fault Red Blinking Panel ...

Страница 14: ...12 System Status List Weather Carousel Menu Interactive Shield and System Arming Status Keypad Interface TODAY WEDNESDAY 82 98 77 HI LO CURRENT 98 77 HI LO Interactive Dealer Logo ...

Страница 15: ...lows the system to be quickly armed and disarmed It also displays the system s current arming status System Status List This portion of the keypad displays the current system status list which allows the end user to scroll though information such as date and time weather armed or ready status and other system generated messages Weather The weather area displays the current weather conditions based...

Страница 16: ... right edge of the keypad housing This is used to load a custom logo onto the main screen Insert the Micro SD card straight in with the contacts facing the wall pressing in until a click occurs from the spring mechanism To remove the Micro SD card gently press in to allow the spring to eject the card Grasp the edges of the card with two fingers and remove See Figure 6 1ABC 5MNO 9YZ 2DEF 6PQR 0 3GH...

Страница 17: ...s menu This icon can be seen in Figure 7 Press the panic menu icon for 2 seconds until a beep is heard At the beep the panel sends the following zone alarm reports to the central station Panic Zone 19 Device Address Emergency non medical Zone 29 Device Address Fire Zone 39 Device Address DISARMED NOW TUE Panic Chime Check in Reset MONITOR ON PANIC OPTIONS PRESS AND HOLD BUTTON TO SEND FIRE POLICE ...

Страница 18: ... Speaker Tone Set the keypad speaker tone for screen presses At the SET TONE display use the left to lower the tone and the right to raise the tone Internal Volume Level Set the keypad speaker volume level for screen presses entry delay and zone monitor conditions During alarm entry delay and trouble tone conditions the volume is always at maximum level Use the left to decrease the keypad volume a...

Страница 19: ...ode selectively enable the Panic keys Bypass Request to Exit and set entry card options Note All programming options display on all keypad models However actual operation for some programming options is restricted to the appropriate model Keypad Options KPD OPT To program keypad options press KPD OPT Keypad Address Set the keypad address from 01 to 08 for XT30 XT50 or 01 to 16 for XR150 XR550 Seri...

Страница 20: ...ammed value other than zero Default Keypad Message Enter a custom message of up to sixteen characters to appear on the keypad display top line whenever that line is not used for any other purpose Press any select area to clear the current message and enter a new custom display Arm Panic Keys Use this option to configure the panic icons To enable or disable a panic icon press the icon name PN Panic...

Страница 21: ...contact restores to normal Ten seconds before the bypass entry exit time expires the keypad beeps once every second If the door remains open when the timer expires a zone open short is sent to the panel for Zone 2 The default is forty seconds Figure 10 shows how the bypass works using the default forty second timer ACTIVATE ZONE 2 BYPASS NO YES ZONE 2 BYPASS TIME 40 5 Second Strike 40 Second Bypas...

Страница 22: ...he time programmed in the Zone 3 REX Strike Time the relay restores the door to its locked state No panel programming is required Zone 3 REX Strike Time 7873 only Enter the number of REX seconds to elapse Range is from 5 to 250 seconds Press the display to enter the number The default is 5 seconds Number of User Code Digits The keypad recognizes user codes from 4 to 10 digits in length Press the d...

Страница 23: ...data string To save the DMP option press DMP and then press CMD Select CUSTOM if using a non DMP credential To select CUSTOM press the right side of the display When CUSTOM displays press CMD Default is DMP Wiegand Code Length When using a custom credential enter the total number of bits to be received in Wiegand code including parity bits Press the display to enter a number between 0 255 to equal...

Страница 24: ...fault is 8 User Code Position Define the User Code start bit position Press any select area to enter a number between 0 255 Press CMD to save the entry Default is 9 Figure 11 HID 26 Bit Wiegand Data Stream Bit Location Example 0 1 1 1 0 1 0 1 1 0 1 1 0 1 0 1 0 0 0 1 1 0 0 1 1 1 First Bit Received Position 0 Site Code Position 1 Length 8 User Code Position 9 Length 16 Last Bit Received Position 25 ...

Страница 25: ...ntry option matches the site code received in the Wiegand string You can program up to 8 three digit site codes Note A card with a site code greater than three digits cannot be used Use only cards with three digit site codes Site Codes 1 4 Enter site codes 1 4 left to right separated by sign Press the sign to add delete or change the site code Press CMD to save the entry Site code range is 0 999 S...

Страница 26: ... Wiegand site code string received matches any site code programmed at SITE CODE ENTRY For details refer back to the REQUIRE SITE CODE option 4 Press ANY to choose Any Wiegand Read Door access is granted when any Wiegand string is received 5 Press ON to choose Relay Always On The relay is always on 6 Press the CMD key to display the next action 7 Press LAST to choose Keep Last State The relay rema...

Страница 27: ... right side of the keypad Select ADD to upload the file The keypad will display ADDING LOGO SURE Select YES to proceed While the logo is being uploaded the keypad displays ADDING LOGO ADDING LOGO COMPLETED displays to confirm a successful upload Select ADD at the DEALER INFO prompt to include information about the dealer when the logo is pressed on the main screen The keypad displays ADDING INFO S...

Страница 28: ...telabel dmp com for information about acquiring a logo Carousel Z Wave Items The Carousel Z Wave Items screen allows you to select the Z Wave options to be displayed in the Carousel menu on the main screen Press the item to select and a check mark displays Press again to de select Items for the carousel include Lights Doors Thermostats and Favorites Pressing CMD at the bottom of the screen advance...

Страница 29: ...es screen If NO is selected the Edit Z Wave icon will not be displayed See Figure 13 Select Language The Select Language screen allows you to select the language for text on the home screen and carousel menu screens Press the item to select and a check mark displays Only one language may be selected Default is English See Figure 14 Note The keypad does not translate information from the panel that...

Страница 30: ...er Menu 3577 choose KPD OPT and press CMD to the new Restart Keypad screen just after Select Language 5 Press RESTART The keypad will load the new firmware from the Micro SD card and then the keypad automatically restarts Caution Do not remove the Micro SD card or disrupt power during this process 6 When the keypad restart is complete remove the Micro SD card from the keypad CMD RESTART Press the ...

Страница 31: ...the four protection zones The status is shown as OPEN SHRT or OKAY Note The Zone Test displays on other keypads without built in zones but is not operational Input Wiegand This option tests the internal and external reader input from proximity credentials The display shows OKAY each time a good proximity read is received Exiting the Installer Options STOP Press the CMD key until the display return...

Страница 32: ...ds are not compatible with iClass There are custom and non standard credentials from HID that are not compatible with DMP proximity keypads If you are using HID cards that have not been purchased directly from DMP it is recommended to thoroughly test the application fully before installation DMP does not guarantee compatibility with credentials not purchased from DMP Proximity Credentials Compatib...

Страница 33: ...Arming and Disarming Area System Arming and Disarming Press the lock icon and select the arming disarming option The keypad displays ENTER CODE Present a card to the reader Once validated by the system all areas assigned to your code arm or disarm automatically and the 7873 keypad door strike relay activates See Figure 16 End User Training RESET 1ABC 5MNO 9YZ 2DEF 6PQR 0 3GHI 7STU 4JKL 8VWX CMD AL...

Страница 34: ...eas automatically arm in the AWAY mode Keypad Access Control Area and All Perimeter Door Strike From the Status List present a card to the reader Once the system validates the card the Door Strike relay activates Home Away systems only activate the 7873 Door Strike relay when arming and disarming See Figure 17 ARMED Panic Chime Check in Fire Reset MON 5 35 AM While the keypad displays the Status L...

Страница 35: ...873 door strike relay Area systems provide a delay to allow selected areas only to be disarmed See Figure 18 End User Training RESET 1ABC 5MNO 9YZ 2DEF 6PQR 0 3GHI 7STU 4JKL 8VWX CMD ALL CHIME PERIM HOME SLEEP USER MENU ENTER CODE Entry delay starts The System disarms the area and activates the Door Strike Relay RESET 1ABC 5MNO 9YZ 2DEF 6PQR 0 3GHI 7STU 4JKL 8VWX CMD ALL CHIME PERIM HOME SLEEP ENT...

Страница 36: ...rmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televis...

Страница 37: ... interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptib...

Страница 38: ...e installed within the protected area and all REX devices must be Listed to UL 294 Certifications California State Fire Marshall CSFM FCC Part 15 RFID Reader FCC ID CCKPC0131 Industry Canada ID 5251A PC0131 ANSI UL 294 Access Control System Units ANSI UL 365 Police Connected Burglar ANSI UL 609 Local Burglar ANSI UL 1023 Household Burglar ANSI UL 1076 Proprietary Burglar ANSI UL 1610 Central Stati...

Страница 39: ......

Страница 40: ...LT 1162 1 03 17274 ...

Отзывы: