24
No Communication With Panel
This option defines the relay action when communication with the panel has not occurred
for five seconds. Press any select area to display CHOOSE ACTION. The default is Relay
Always Off.
1.
Choose the No Communication with Panel action that is
required.
2. Press OFF to choose the default of Relay Always Off.
The relay does not turn on when any Wiegand string is
received and does not affect any REX operation.
3. Press SITE to choose (Accept Site Code) — Door access
is granted when the Wiegand site code string received
matches any site code programmed at SITE CODE
ENTRY. For details refer back to the REQUIRE SITE CODE
option.
4. Press ANY to choose (Any Wiegand Read) — Door
access is granted when any Wiegand string is received.
5. Press ON to choose (Relay Always On) — The relay is
always on.
6. Press the CMD key to display the next action.
7.
Press LAST to choose (Keep Last State) — The relay
remains in the same state and does not change when
communication is lost.
8.
After choosing the action, the NO COMM WITH PNL
option and the newly defined action display. Press CMD
to save the entry. Press the back arrow to return to
REQUIRE SITE CODE:.
CHOOSE ACTION
LAST
CHOOSE ACTION
OFF SITE ANY ON
Installer Options