Arming/Disarming Wait Time
Select the number of seconds (1-9) the keypad should wait
when an area system displays ALL? NO YES during arming/
disarming or a HOME/SLEEP/AWAY system waits during
arming only. If NO or YES, or HOME, SLEEP, or AWAY is
not manually selected before the delay expires, the keypad
automatically selects the YES or the AWAY key. Enter zero
(0) to disable this feature. The delay also occurs when any
credential is presented for arming the HOME/SLEEP/AWAY
system.
DMP Card Option
Select DMP to indicate the reader sends a twenty-six
bit DMP data string. To save the DMP option, press DMP
and then press CMD. Select CUSTOM if using a non–DMP
credential. To select CUSTOM press the right side of the
display. When CUSTOM displays, press CMD. Default is DMP.
Wiegand Code Length
When using a custom credential, enter the total number of
bits to be received in Wiegand code including parity bits.
Press the display to enter a number between 0-255 to equal
the number of bits. Default is 26 bits. Typically, an access
card contains data bits for a site code, a user code, and
start/stop/parity bits. The starting position location and
code length must be determined and programmed into the
keypad. Refer to Figure 11 on the next page.
CARD OPTIONS
DMP
CUSTOM
WIEGAND CODE
LENGTH 26
ALL?:
NO YES
DELAY: 2
Installer Options