Form C Relay
The 10 Amp Form C relay draws up to
35 mA of current. Refer to “Wire the
Access Control Lock” and “Isolation Relay
(optional)” in this document for more
information.
Programming Connection
The modules also provide a keypad
programming connection that allows
you to use a standard DMP LCD keypad
for initial setup. Programming can be
completed using a keypad connected to
the module or from XR150/XR550 panels.
Wiegand and OSDP Reader
Support
The 734N Series supports both Wiegand
and OSDP card readers. For information
on compatible readers, refer to “Readers
and Credentials”. OSDP support requires
734N/734N‑POE modules with PCB Rev 9
and higher.
Local Event Storage
When communication is lost with the
panel, 734N and 734N‑POE Access
Control Modules store access granted
events locally in module memory. When
communication is reestablished, stored
events are sent and synced with panel
events, then inserted into the event buffer
according to the actual time when they
occurred. To enable local event storage,
CARD FORMAT
must be set to
DMP
or
CUSTOM
and
NO COMM WITH PNL
must
be set to
SITE
or
ANY
.
Local Event Storage requires 734N/734N‑
POE modules with firmware Version 105
or higher, along with XR Series firmware
Version 202 or higher.