Digital Monitoring Products, Inc. | 734B Installation and Programming Guide
5
Wire the Magnetic Lock
The 734B provides a Form C (SPDT) relay for controlling locks and other
electronically‑controlled barriers. The three relay terminals marked NO C NC allow
you to connect the device wiring to the relay for module control.
Use an additional power supply to power magnetic locks and door strikes. See
Figure 3 and Figure 4 for typical magnetic lock and door strike wiring.
The Form C relay draws up to 35 mA of current and contacts are rated for 10 Amps
(resistive) at 12/24 VDC. When connecting multiple locks to the Form C relay, the
total current for all locks cannot exceed 10 Amps. If the total current for all locks
exceeds 10 Amps, problems may arise and an isolation relay may be needed. See the
Isolation Relay section for information.
2
PROG
J2
RED
RED
KYPD IN
J4
J1
DATA
XMT LED
WIEGAND
READ LED
RELAY
ON
NC
C
NO
GRN
YEL
RED
Model 333
Suppressor
Normally Closed
–
+
Magnetic Door Lock
12/24 VDC
Power Supply
Figure 3: Typical Magnetic Lock Wiring
PROG
J2
RED
J1
DATA
XMT LED
WIEGAND
READ LED
RELAY
ON
NC
C
NO
GRN
YEL
RED
Model 333
Suppressor
Normally Open
–
+
DC Door Strike
12/24 VDC
Power Supply
Figure 4: Typical Door Strike Wiring
Содержание 734B
Страница 1: ...INSTALLATION AND PROGRAMMING GUIDE 734B Access Control Module...
Страница 2: ......
Страница 4: ......
Страница 34: ...30 734B Installation and Programming Guide Digital Monitoring Products Inc...
Страница 35: ...Digital Monitoring Products Inc 734B Installation and Programming Guide 31...
Страница 36: ...LT 1952 20055 2020 Digital Monitoring Products Inc...