1119 Wireless Door Sounder
Description
The Model 1119 Wireless Door Sounder is a single-zone transmitter equipped with a battery powered sounder.
The 1119 provides a cover tamper, a sounder cutoff selection of one second or five minutes, survey LED, and two
batteries. The 1119 zone input can be connected to a standard door contact, typically attached to an emergency
exit door for local annunciation during the day and burglary alarm annunciation at night. The sounder always
automatically turns on when the door opens. The 1119 sounder is silenced after one second or five minutes or can be
silenced remotely from the panel at disarm or from the user menu.
Compatibility
• All DMP 1100 Series Wireless Receivers and Burglary Panels
What is included
The 1119 includes the following:
• One 1119 with zone input and wireless sounder
• Two 3.0V Lithium CR123A batteries
• Hardware pack with 470k EOL Resistor
• Serial number labels
Serial Number
For your convenience, two additional pre-printed serial number labels are
included for the zone and sounder output. Prior to installing the wireless
sounder, record the serial numbers or place the pre-printed serial number
labels on the panel programming sheet. One serial number is for the input
zone and the other is for the output. These numbers are required during
programming.
Sounder Cutoff Jumper
The 1119 provides a sounder cutoff jumper (J5) that causes the 1119 to automatically turn off the
sounder after one second or five minutes depending on the jumper position.
When the onboard 1119 zone is tripped, the 1119 turns on the sounder output for one second if the
jumper is placed on the two left pins or for five minutes if the jumper is placed on the two right
pins.
When the sounder output is programmed in Output Information and is turned on by an output
command from the panel such as a different zone trip, group output, or manually from a keypad, the 1119 always
turns the sounder output off automatically after five minutes regardless of the position of the jumper (J5).
In addition, when the sounder output was turned on by a panel output command and then automatically turned off
by the 1119 after five minutes, the sounder output cannot be turned back on by the panel until the 1119 receives a
panel output off command as described below.
Silencing the Sounder
The following panel operations can silence (turn off) the sounder:
• Bell Output (XR100/XR500)
Program the output in Bell Output so the output turns off at the Bell Cutoff time if less than five minutes.
• Disarming (All panels)
Program the output in the Alarm Action output section of the zone that will be disarmed and set the action
to Steady
• Outputs On/Off (All panels)
From the User Menu, choose Outputs On/Off, enter the output number and choose Off
• Output follows 1119 zone condition (All panels)
Program the output in the Alarm Action output section of the 1119 zone programmed in Zone Information
and set the action to Follow. When the 1119 zone restores, the output is turned off.
See Programming the 1119 in the Panel section for additional information.
Zone Bypassed
When the 1119 sounder output (programmed in Output Information) and in the Alarm Action output section of Zone
Information becomes bypassed in the panel, subsequent tripping of the 1119 zone turns on the sounder but because
the 1119 panel zone is bypassed, the panel turns off the sounder output within a few seconds.
Figure 1: 1119 Wireless Sounder
SOUNDER
CUTOFF
1
SEC
5
MIN
InstallatIon GuIde