― 30 ―
― 29 ―
Range
Frequency measurement (Hz)
Input sensitivity (Sine wave)
Frequency range
9.999 V
2.5 V
15.00 Hz to 10.00 kHz
99.99 V
25 V
999.9 V
100 V
The display style of [Hz/
@GRHVQRWVKRZWKHEDUJUDSK
As a normal condition, non-connected test leads may cause
unstable readings.
5-4
「
」
(Max. rated input voltage: 1,000 V dc/ac)
・
DC Voltage( ) measurement
・
DC Voltage( )/AC Voltage( ) simultaneous measurement
・
DC+AC voltage( )/AC Voltage( ) simultaneous
measurement
1) What to measure
・
(DC Voltage): Batteries, DC circuit voltages, etc.
・
/ (DC voltage component/AC voltage component)
・
/ (DC/AC superimposed signal voltage/AC voltage
component)
2) Measuring ranges
・
, / , / : 9.999 V, 99.99 V, 999.9 V
3) Measuring procedure
①
Connect the red plug of the test lead to the V measuring
terminal and the black one to the COM terminal.
②
Set the function selector to
.
③
Press the SELECT button to select a function you want to
perform.
④
Apply the test pins (Red and Black) to the object to
measure.
⑤
Read the display.
1. Do not apply any input signal exceeding the max. rated input voltage.
2. Do not switch the function selector while measuring.
3. Keep your fingers behind the finger guards of the test leads while
measurement.
WARNING
Содержание SANWA PC720M
Страница 1: ...PC720M DIGITAL MULTIMETER INSTRUCTION MANUAL...
Страница 18: ...32 31 Note The display style of RU GRHV QRW VKRZ WKH EDU JUDSK...
Страница 20: ...m m D 36 35 Note The display style of m m P m or GRHV QRW VKRZ WKH EDU JUDSK...
Страница 24: ...T1 T1 T2 T1 T2 44 43...
Страница 29: ...Hz 54 53...