Mega Power -
Liquid Ring Vacuum Pump
8
Every 1 year Maintenance Clean Water Inlet strainer (Y- type)
If main tap water condition is not clean, check the water inlet strainer if
necessary or every 1 year.
The water inlet strainer has small wire mesh inside to remove rust.
Use large crescent wrench to remove nut. With air gun clean mesh inside of
strainer and then re-assemble. The nut should be tightened not to be leaks.
Cleaning filter (Every week)
Cleaning water inlet strainer (If necessary or every 1 year)
Содержание Mega Power I
Страница 3: ...3 2 Product Structure 1 Explosive view of product...
Страница 6: ...Mega Power Liquid Ring Vacuum Pump 6 4 Installation Instruction A Plumbing drawing...
Страница 10: ...Mega Power Liquid Ring Vacuum Pump 10...
Страница 13: ...13 Part List...