6
12/13 REV. G FILE #: SCTP-DS
COPYRIGHT © 2010 Daniels Manufacturing Corp ALL RIGHTS RESERVED
DANIELS MANUFACTURING CORP. 526 THORPE ROAD, ORLANDO, FL 32824, USA
PHONE (407) 855-6161 • FAX (407) 855-6884 •w ww.DMCTools.com • E-MAIL: [email protected]
3.4
Insert the free end of the cable through the last ferrule in the cartridge as shown in figure 10. Remove
the ferrule by pulling the cable away from the end of the cartridge.
CAUTION: DO NOT RELEASE THE FREE END OF THE CABLE UNTIL IT HAS BEEN INSERTED
THROUGH THE NOSE.
3.5.
Insert the free end of the cable through the nose as shown in figure 11. Slide the tool along the
cable to the desired position.
3.6
Rotate the cable tensioning wheel with the cable entry slot up to the position shown in figure
12. Position the nose such that the ferrule is pressed squarely against the fastener. Make
certain that the ferrule is fully seated in the nose.
3.7
Insert the free end of the cable into the cable entry slot of the cable tensioning wheel. When
the free end of the cable appears at the bottom of the wheel, grab the cable and pull slack from
the cable. Do not leave more than 1 1/2" of slack in the cable (figure 13).
3.8
Press the trigger and hold.
CAUTION: IT IS IMPORTANT TO HOLD THE TOOL STEADY AND PERPENDICULAR TO THE CABLE
DURING THE CRIMPING CYCLE TO MAINTAIN CONSISTENT TENSION (FIGURE 12).
FERRULE
NOSE
FREE END
OF CABLE
FIGURE 11
CARTRIDGE
FREE END OF CABLE
FERRULE
FIGURE 10