DMC SCTP Series Скачать руководство пользователя страница 1

1

12/13          REV. G          FILE #: SCTP-DS

COPYRIGHT © 2010  Daniels Manufacturing Corp  ALL RIGHTS RESERVED

DANIELS MANUFACTURING CORP.  526 THORPE ROAD, ORLANDO, FL 32824, USA

PHONE (407) 855-6161 • FAX (407) 855-6884 • w ww.DMCTools.com • E-MAIL: [email protected]

DATASHEET

SCTP SERIES

SCTP SERIES

SCTP SERIES

SCTP SERIES

SCTP SERIES

PNEUMATIC SAFE-T-CABLE

PNEUMATIC SAFE-T-CABLE

PNEUMATIC SAFE-T-CABLE

PNEUMATIC SAFE-T-CABLE

PNEUMATIC SAFE-T-CABLE

®

 TOOL

 TOOL

 TOOL

 TOOL

 TOOL

SEE PAGE 11 FOR IMPORTANT INFORMATION CONCERNING LIMITED

WARRANTY, AND LIMITATION OF LIABILITY

INTRODUCTION

The Daniels SCTP Series Pneumatic Safe-T-Cable

®

 application tool is designed to crimp ferrules, and

tension/cut the cable in accordance with the performance requirements of SAE specification AS4536*.
The application tool installs Safe-T-Cable

®

 kits identified in SAE specifications AS3509*, AS3510* and

AS3511*.

The following steps are important:

1. Proper tool setting (section 1.0)
2. Proper cable installation (section 2.0)
3. Proper loading and use of the application tool (section 3.0)
4. Verification of proper application (section 4.0)

* SAE publications are available from:

SAE, International
400 Commonwealth Drive
Warrendale, PA 15096-0001

1.0 TOOL MAINTENANCE AND VERIFICATION OF TOOL SETTINGS

1.1 Checking Indenter Settings with the Daniels SCT-TB1 Torque Verification Block

1.1.1. Indenter settings should be checked periodically and must be checked after the nose assembly has

been removed or changed.

1.1.2. Thread the cable into the left swivel and through the right swivel, holding the lever in the

home position as shown in figure 1. If the lever is not kept in the home position the results
may be adversely affected. Terminate the cable per section 3.0.

1.1.3. Apply approximately 2 lb force to the cable with your finger (or use the Daniels SCTD013 Retention

Tester) at the line marked "TEST AREA". If the cable touches either the side or bottom surface of
the test area, remove the cable from the block. Properly terminate another cable, holding the tool
perpendicular to the cable and making certain that there is no more than 1 1/2 inch of slack.

LEVER

RIGHT SWIVEL

MOUNTING HOLES

LEFT SWIVEL

FIGURE 1

Содержание SCTP Series

Страница 1: ...0 3 Proper loading and use of the application tool section 3 0 4 Verification of proper application section 4 0 SAE publications are available from SAE International 400 Commonwealth Drive Warrendale...

Страница 2: ...e proper pull off load as shown in table 2 CAUTION RELEASE TORQUE WHEN MINIMUM PULL OFF IS ACHIEVED DO NOT APPLY ADDITIONAL TENSION TO THE CABLE 1 1 5 If the cable did not break or pull out of the fer...

Страница 3: ...AYDAMAGE THE TOOL 1 3 RELEASING THE INDENTER 1 3 1 The SCTP series pneumatic Safe T Cable tool has an internal cycle control feature which prevents the indenter from returning if the crimping cycle is...

Страница 4: ...5 3 Coat the cavity with a light film of any lightweight synthetic or petroleum based oil after the cavity has been thoroughly cleaned 2 0 PROPER CABLE INSTALLATION 2 1 Various examples of Safe T Cabl...

Страница 5: ...MCTools com E MAIL DMC DMCTools com FIGURE 9 FIGURE 7 TUBE COUPLINGS TOOL BODY FIGURE 8 OTHER APPLICATIONS 3 0 PROPER LOADINGAND USE OFTHEAPPLICATION TOOL 3 1 Connect the tool to a clean dry air suppl...

Страница 6: ...the desired position 3 6 Rotate the cable tensioning wheel with the cable entry slot up to the position shown in figure 12 Position the nose such that the ferrule is pressed squarely against the fast...

Страница 7: ...and slide the tool off the crimped ferrule Pull the excess cable from the tool 4 0VERIFICATION OFINSTALLATION 4 1 Verify proper tension of the cable Refer to table 1 figure 14 for Safe T Cable flex l...

Страница 8: ...EX LIMITS DIMENSIONS A inch mm 0 5 12 7 1 0 25 4 2 0 50 8 3 0 76 2 4 0 101 6 5 0 127 0 6 0 152 4 FOR THREE BOLT PATTERNS A D E FIGURE 14 HANDAPPLICATIONTOOLS INTERCHANGEABLE NOSES TOOL PARTNUMBER SCT2...

Страница 9: ...0 3 8 3 0 4 0 0 4 6 DMC KIT PART No DMC CABLE ASS Y PART No DMC FERRULE PART No DOCUMENT NUMBER EX AS3509 AS3510 AS3511 EXAMPLE PART NUMBER A KIT CONFORM ING TO AS3510 032 038 CABLE D I A M E T E R 1...

Страница 10: ...0 CORROSION AND HEAT RESISTANT ALLOY AMS5689 KIT PART NUMBER A10 106 A10 109 A10 112 A10 115 A10 118 A10 121 A10 124 A10 206 A10 209 A10 212 A10 215 A10 218 A10 221 A10 224 A10 306 A10 309 A10 312 A10...

Страница 11: ...over any damage to any product which in the opinion of DMC was caused by normal wear misuse improper operation tampering neglect or accident This warranty is in lieu of all other warranties express or...