DLP Design DLP-RFS1280 Скачать руководство пользователя страница 9

Rev 1.7 (April 2018)                                               9                                                  

¤

 DLP Design, Inc. 

exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit 
pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage  
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. 

 

Note:  In the event that these conditions cannot be met (i.e. co-location with another transmitter), then 
the FCC authorization is no longer valid, and the corresponding FCC ID may 

not

 be used on the final 

product.  Under these circumstances, the OEM integrator will be responsible for re-evaluating the end 
product (including the transmitter) and obtaining a separate FCC authorization. 
 

 

7.5  OEM PRODUCT LABELING

 

 

The end product containing the DLP-RFS1280 must be labeled in a visible area with the following 
text: 
 

“Contains FCC ID:  SX9RFS2” 
 

L’étiquette d’homologation d’un module d’Innovation, Sciences et Développement économique 
Canada devra être posée sur le produit hôte à un endroit bien en vue, en tout temps. En l’absence 
d’étiquette, le produit hôte doit porter une étiquette sur laquelle figure le numéro d’homologation du 
module d’Innovation, Sciences et Développement économique Canada, précédé du mot « contient », 
ou d’une formulation similaire allant dans le même sens et qui va comme suit: 

 

“Contient IC:  5675A-RFS2 est le numéro d’homologation du module.” 

 
 

7.6  RF EXPOSURE

 

 

This equipment complies with FCC and IC RSS-102 radiation-exposure limits set forth for an 
uncontrolled environment.  This equipment should be installed and operated with a minimum distance 
of 20cm between the radiator and a human body.  This transmitter must not be co-located or 
operating in conjunction with any other antenna or transmitter. 
  

Cet équipement est conforme aux limites d'exposition aux radiations fac et IC CNR-102 établies pour 
un environnement non contrôlé.  Cet équipement doit être installé et utilisé avec une distance 
minimale de 20 cm entre le radiateur et votre corps.  Cet émetteur ne doit pas être co-implanté ou 
fonctionner en conjonction avec toute autre antenne ou transmetteur. 

 
 

7.7  ADDITIONAL INFORMATION FOR OEM INTEGRATORS

 

 

The end user should not be provided with any instructions on how to remove or install the  
DLP-RFS1280.  This device has been certified to operate with the antenna models listed below: 
 

x

  On-board Chip Antenna 

x

  Antenna Factor / Linx ANT-2.4-PML-UFL 

 
 
 
 
 

Содержание DLP-RFS1280

Страница 1: ...ely APPLICATION AREAS x Real Time Security x Body Worn Medical Telemetry x Battery Powered Home Automation x Electric Water Gas Automated Meter Reading x Industrial Monitoring and Control x Active RFID x Long Range Battery Powered Multi Hop Sensor Networks 1 0 INTRODUCTION The DLP RFS1280 is a low cost module for transmitting and receiving digital data via radio frequency All of the DLP RFS1280 s ...

Страница 2: ...s Interface SPI Operational Power Transmit 24mA Operational Power Receive 4 8mA 5 6mA Depending Upon the Operating Mode Operational Power Sleep 8uA Deepest Sleep Mode Antenna Connector u fl Operating Temperature 0 70 C Please see the Antenna Section for important regulatory details 3 0 IO PINS IO Pin Definitions 1 GROUND 2 NRESET 3 BUSY 4 DIO1 5 DIO2 6 DIO3 7 MISO_TX 8 GROUND 9 3 3V POWER SUPPLY 1...

Страница 3: ... MECHANICAL DRAWING Overall Dimensions 0 8 x 0 92 x 0 135 In Note thou mils or 0 001 inches 4 2 MOUNTING OPTIONS The DLP RFS1280 module can be either surface mounted to a printed circuit board or connected using 0 1 inch spaced headers 0 025 sq inch posts ...

Страница 4: ... been developed for the STM32L073RZ based Nucleo board Compiling the L073 source code may require the user to purchase the Keil compiler Additional information on the operation of the Semtech SX1280 transceiver IC is available in the datasheet for the SX1280 6 0 DEMONSTRATION HARDWARE EDK This section describes how to operate the DLP RFS1280ACT demonstration hardware purchased separately The DLP R...

Страница 5: ...ile holding Button 1 press and release RESET Continue to hold Button 1 until you hear a beep Release Button 1 and the system will be transmitting at 2 4GHz on the internal chip antenna with no modulation Be sure to turn the volume up blue knob next to the speaker if you cannot hear the beep You can change to the external antenna by pressing Button 2 ANT SEL The display will show either a C for chi...

Страница 6: ... a beep Release Button 3 and the system will be transmitting at 2 4GHz on the internal chip antenna with GFSK modulation 6 5 PAIRING Each Nucleo board has a unique serial number that is created by combining wafer data stored in silicon within the STM32 microcontroller This serial number is generated after each reset and is then presented on the LCD display of the DLP RFS1280ACT Pairing is the proc...

Страница 7: ...y of three modulation modes LORA GFSK or FLRC 6 7 PUSH TO TALK WALKIE TALKIE MODE The Push To Talk function is a rudimentary demonstration of packetizing and transmitting audio in LORA Mode using Spreading Factor 6 This demonstration is not intended to provide high audio quality 6 7 1 Press Button 1 on each transceiver until LORA mode is shown on the LCD display of both platforms 6 7 2 Press Butto...

Страница 8: ...oard antenna or pre approved external antenna could void the user s authority to operate this equipment Other external antennas can be used with the DLP RFS1280 module so long as the maximum legal radiated power limit is not exceeded 7 4 WARNINGS Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference rece...

Страница 9: ...tte sur laquelle figure le numéro d homologation du module d Innovation Sciences et Développement économique Canada précédé du mot contient ou d une formulation similaire allant dans le même sens et qui va comme suit Contient IC 5675A RFS2 est le numéro d homologation du module 7 6 RF EXPOSURE This equipment complies with FCC and IC RSS 102 radiation exposure limits set forth for an uncontrolled e...

Страница 10: ...ular purpose is either made or implied DLP Design will not accept any claim for damages whatsoever arising as a result of the use or failure of this product Your statutory rights are not affected This product or any variant of it is not intended for use in any medical appliance device or system in which the failure of the product might reasonably be expected to result in personal injury This docum...

Страница 11: ...it With Modulation Reset Required to Exit Switch 5 Pressed Switch 6 Pressed Enter Ping Test Mode One Ping Per Second Reset Required to Exit Enter Ranging Mode Reset Required to Exit 4 1 5 2 6 3 CW LORA FSK FLRC ANT SEL MOD PTT RX ID PING TEST LMH SF RANGING 7 BUTTONS RESET Enter Receive Mode Ping Packet Received Beep Once If MyID was Received Audio Packet Received Play Audio Over Speaker if MyID w...

Страница 12: ... Registers Enter Receive Mode Waiting for Ranging Packet Replies Sent Automatically Set Packet Type and Parameters For Ranging SF6 SF10 Load the Shared 32 Bit Ranging Address Mode Entered from Reset Receive Packet With RSSI and Frequency Error Data From Slave Set Packet Type and Parameters for Ranging Mode SF6 SF10 Depending on RSSI Load the Shared 32 Bit Ranging Address Select Ranging Interrupts ...

Отзывы: