Web Power Switch
Pro
14
Specifications
Applications
Test equipment. Commercial, industrial, and
residential remote power control and reboot
Indoor use only
Audio Alert
73dBa at 12” programmable
Circuit Breakers
Manual reset, 15A Thermal Supplemental, UL
Clock / RTC
15 year Li battery, under 2 grams
Controls / Display
Reset -to-factory-default switch, 2x16 Backlit LCD
w/ PowerSave, 5 button keypad, manual reset
Enclosure
Steel, double grounded. Vented 4 sides. Fanless.
Ethernet Interface
10/100 autosensing, Static IP, TCP port selectable,
8 pin RJ-45 w/ internal FCC filtering
FCC Testing
Part 15 FCC ID 2ACIUPRO
Humidity
8-80% RH Operating
Input Power Cord
Removable 16-14AWG 120VAC C-19
Inlet and Outlet Rating UL, CSA 15A, 5-15,120VAC only
Input Frequency
Power supply - DC-400Hz
Operating Temperature -30º to 170ºF, -34º to 77ºC
Options - Factory
Input cord length and 120V plugs, rack bracket
Power Supply Rating
90-240V, AC/DC Autosensing
Password Transmission Encrypted, base 64 or HTTPS
Power Dissipation
3.9W Typ Max (all on) <3 W idle
Power Fail Hold-Over
200ms minimum (all relays on)
Power-Up Modes
Last used settings, all power on or off, sequential
on or run user-script ~30s after power-up
Protocall Support
Alexa, HTTP, HTTPS, IFTTT, SSH, SSL, MQTT, Lua,
SNMP, JABBER, SYSLOG, RESTful API, MODBUS,
EMAIL, XMPP, UPNP
Relay Specs
40A AC NO, 1/2HP, 12V DC coil
Surge Protection
3600W Metal Oxide Varistor
Size
5.5x13.7x1.6’”
Weight (packed)
Single unit 4.7lbs 2.2kg
WiFi
Atheros 9331 2.4G 802.11n RP-SMA - FCC Note:
The EPCR5 may only be used with (1) the manu
facturer supplied antenna (Gain: 2.0dBi),or (2) a
50 Ohm antenna of equal or lesser gain.