background image

50  |  AC04G(X) man.

SCHÉMAS

FRANÇ

AIS

Содержание AC04G

Страница 1: ...R USER MANUAL CUSTOMER SERVICE 1 888 277 6960 WWW DK2 COM DK2 USA WEST 3311 MEADE AVENUE STE E DOCK 13 LAS VEGAS NEVADA 89102 USA DK2 USA EAST 3750 SOUTH AVENUE NORTH UNIT TOLEDO OHIO 43615 USA DK2 CORPORATE HEAD OFFICE 5330 MAINWAY BURLINGTON ONTARIO L7L6A4 CANADA ...

Страница 2: ...OR APPLY TO a Damage to the product due to misuse mishandling and abuse b Improper installation maintenance and storage c Expendable parts such as nuts and bolts pins and springs wiring and switch components hydraulic hoses and fittings cutting teeth cutting chains cutting blades throttles belts and tires d Normal wear and tear e Consequential damage incidental damages such as damage to persons or...

Страница 3: ...ON II INSTALLATION 11 LOCATION 12 ELECTRICAL INSTALLATION 12 GROUNDING INSTRUCTIONS 12 EXTENSION CORDS 13 SECTION III OPERATION 14 COMPONENTS 15 LUBRICATION 15 BREAK IN PROCEDURE 16 SAFETY VALVE 17 REGULATOR KNOB 17 TANK PRESSURE GAUGE 17 SECTION IV MAINTENANCE 18 THERMAL OVERLOAD PROTECTOR 19 STORAGE 19 MAINTENANCE PROCEDURE SCHEDULE 20 TROUBLESHOOTING 20 SECTION V PARTS SCHEMATICS 22 PARTS LIST ...

Страница 4: ... 60Hz SPEED 1700RPM DISPLACEMENT 3 8CFM 4 0CFM MAX PRESSURE 125PSI DECIBELS 67dB DIMENSIONS 17 4 L x 15 6 W x 20 8 H 44 2cm L x 39 5cm W x 52 8cm H WEIGHT 54lb 24 5kg SHIPPING DIMENSIONS 18 7 L x 16 5 W x 22 4 H 47 5cm L x 42cm W x 57cm H SHIPPING WEIGHT 57 3lb 26kg WARRANTY 1 year limited ENGLISH ...

Страница 5: ...SECTION I SAFETY ...

Страница 6: ...tions contained in this manual were in effect at printing Equipment described within this manual may be optional Some illustrations may not be applicable to your equipment BEFORE OPERATION WARNING Read carefully and understand all assembly and operation instructions before operating this product Failure to follow the safety rules and other basic safety precautions may result in serious personal in...

Страница 7: ...er and birth defects or other reproductive harm PROPOSITION 65 DE CALIFORNIE Ce produit contient des produits chimiques reconnus par l État de Californie pour causer des cancers et des anomalies congénitales ou d autre dommages à la réproduction WARNING AVERTISSEMENT CALIFORNIA PROPOSITION 65 PROPOSITION 65 DE CALIFORNIE This product contains chemicals known to the state of California to cause can...

Страница 8: ...ard any part of the body or at other people or animals 4 Wear safety glasses and use hearing protection when operating the pump or unit 5 Do not stand on or use the pump or unit as a handhold 6 Before each use inspect compressed air system and electrical components for signs of damage deterioration weakness or leakage Repair or replace defective items before using 7 Check all fasteners at frequent...

Страница 9: ...her accumulations DANGER RISK OF BURSTING Always drain the air compressor tank daily or after each use If the tank develops a leak then replace the air compressor Never use the air compressor after a leak has been found or tried to make any modifications to the tank Never modify the air compressor s factory settings which control the tank pressure or any other function Welding drilling or any othe...

Страница 10: ...has been damaged do not operate the equipment until the proper personnel have correctly repaired the equipment The power cord should be free of any moving parts twisting and or crimping while in use and while in storage WARNING RISK OF FALLING Operation of the air compressor should always be in a position that is stable Never use the air compressor on a rooftop or elevated position that could allo...

Страница 11: ...SECTION II INSTALLATION ...

Страница 12: ...OUNDING INSTRUCTIONS 1 This product is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug shown Fig 1 Make sure the product is connected to an outlet having the same configuration as the plug This product must be grounded In the event of an electrical short circuit grounding reduces risk of electrical shock by providing an escape wire for electric current This ...

Страница 13: ...r this minimum 5 Use a slow blow fuse or a circuit breaker EXTENSION CORDS To avoid voltage drop power loss and overheating of the motor use extra air hose instead of an extension cord Low voltage can cause damage to the motor If an extension cord must be used Use only an approved 3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the air c...

Страница 14: ...SECTION III OPERATION ...

Страница 15: ...he pump to the check valve This tube becomes very hot during use To avoid the risk of severe burns never touch the discharge tube CHECK VALVE A one way valve that allows air to enter the tank but prevents air in the tank from flowing back into the compressor pump HANDLE Designed to move the compressor WARNING Never use the handle on wheeled units to lift the unit completely off the ground DRAIN PE...

Страница 16: ...umps air into the tank It shuts off automatically when unit reaches its maximum preset pressure In the OFF position the pressure switch cannot function and the compressor will not operate Make sure switch Fig 2 is in OFF position when connecting or disconnecting power cord from electrical outlet NOTICE MOISTURE IN COMPRESSED AIR Moisture in compressed air will form into droplets as it comes from a...

Страница 17: ... 3 1 This knob controls air pressure to an air operated tool or paint spray gun 2 Turn clockwise to increase air pressure at outlet When desired pressure is reached lock with nuts 3 To lower air pressure at outlet turn counter clockwise 4 Turn fully counter clockwise to shut off flow of air completely then push knob down TANK PRESSURE GAUGE This gauge shows pressure in tank indicating compressor i...

Страница 18: ...SECTION IV MAINTENANCE ...

Страница 19: ...l OFF NOTICE Locate the unit as far from spraying area as possible as hose will limit over spray from clogging the filter THERMAL OVERLOAD PROTECTOR CAUTION This compressor is equipped with an automatic reset thermal overload protector which will shut off motor if it becomes overheated If thermal overload protector shuts motor OFF frequently look for the following causes 1 Low voltage 2 Clogged ai...

Страница 20: ... fuse 3 Reset determine cause of problem 4 Motor will restart when cool 5 Replace Motor hums but cannot run or runs slowly 1 Defective check valve or unloaded 2 Poor contacts line voltage low 3 Shorted or open motor winding 1 Replace or repair 2 Check connections eliminate extension cork if used check circuit with voltmeter 3 Replace motor DANGER Do not disassemble check valve with air in tank ble...

Страница 21: ...s with soap and water solution and tighten Compressor runs continuously and air output is lower than normal low discharge pressure 1 Excessive air usage compressor too small 2 Clogged intake filter 3 Air leaks in piping on machine or in outside system 4 Broken inlet valves 5 Piston ring worn 1 Decrease usage 2 Clean or replace 3 Replace leaking components or tighten as necessary 4 Replace compress...

Страница 22: ...SECTION V PARTS SCHEMATICS ...

Страница 23: ...ring 6203Z 2 AC04G49X22 49 Power cord 1 AC04G16X22 16 Crank 2 AC04G50X22 50 Horizontal switch 1 AC04G17X22 17 Fan 2 AC04G51X22 51 Rubber hose 1 AC04G18X22 18 Elastic ring Ø14 2 AC04G52X22 52 Unloading pipe 1 AC04G19X22 19 Gate lid 2 AC04G53X22 53 Release pipe 1 AC04G20X22 20 Bearing 6006Z 2 AC04G54X22 54 Unloading valve 1 AC04G21X22 21 Stator subassembly 1 AC04G55X22 55 Handle sleeve 1 AC04G22X22 ...

Страница 24: ...24 AC04G X man SCHEMATICS ENGLISH ...

Страница 25: ... L UTILISATEUR SERVICE À LA CLIENTÈLE 1 888 277 6960 WWW DK2 COM DK2 USA OUEST 3311 MEADE AVENUE STE QUAI E 13 LAS VEGAS NEVADA 89102 ÉTATS UNIS DK2 USA EST 3750 AVENUE SUD UNITÉ NORD TOLEDO OHIO 43615 ÉTATS UNIS SIÈGE SOCIAL CORPORATIF DK2 5330 MAINWAY BURLINGTON ONTARIO L7L6A4 CANADA ...

Страница 26: ...dus à une mauvaise utilisation une mauvaise manipulation et les abus b Installation entretien et entreposage inappropriés c Les pièces consommables telles que les écrous et les boulons les goupilles et les ressorts les composants de câblage et de commutation les flexibles hydrauliques et raccords dents de coupe chaînes de coupe lames de coupe accélérateurs courroies et pneus d Usure normale e Domm...

Страница 27: ...TION 36 EMPLACEMENT 37 INSTALLATION ÉLECTRIQUE 37 INSTRUCTIONS DE MISE À LA TERRE 37 RALLONGES ÉLECTRIQUES 38 SECTION III FONCTIONNEMENT 39 COMPOSANTES 40 LUBRIFICATION 40 PROCÉDURE DE RODAGE 41 SOUPAPE DE SÉCURITÉ 42 BOUTON DE REGULATEUR 42 MANOMÈTRE DE PRESSION DE RÉSERVOIR 42 SECTION IV ENTRETIEN 43 PROTECTEUR DE SURCHARGE THERMIQUE 44 ENTREPOSAGE 44 CALENDRIER DES PROCÉDURES D ENTRETIEN 45 DÉP...

Страница 28: ...ITESSE 1700 tr min DÉPLACEMENT 3 8PCM 4 0PCM PRESSION MAX 125PSI DÉCIBELS 67dB DIMENSIONS 17 4po L x 15 6po L x 20 8po H 44 2cm L x 39 5cm L x 52 8cm H POIDS 54lb 24 5kg DIMENSIONS D EXPÉDITION 18 7po L x 16 5po L x 22 4po H 47 5cm L x 42cm L x 57cm H POIDS D EXPÉDITION 57 3lb 26kg GARANTIE 1 an limité FRANÇAIS ...

Страница 29: ...SECTION I SÉCURITÉ ...

Страница 30: ...ntenues dans ce manuel ont été en vigueur à l impression L équipement décrit dans ce manuel peut être en option Quelques illustrations peut ne pas s appliquer à votre équipement AVANT L UTILISATION AVERTISSEMENT Lisez attentivement et comprenez toutes les instructions de fonctionnement avant d utiliser ce produit Non respect des consignes de sécurité règles et autres précautions de sécurité de bas...

Страница 31: ...to cause cancer and birth defects or other reproductive harm PROPOSITION 65 DE CALIFORNIE Ce produit contient des produits chimiques reconnus par l État de Californie pour causer des cancers et des anomalies congénitales ou d autre dommages à la réproduction WARNING AVERTISSEMENT CALIFORNIA PROPOSITION 65 PROPOSITION 65 DE CALIFORNIE This product contains chemicals known to the state of California...

Страница 32: ...2 Seules les personnes connaissant bien ces règles de sécurité peuvent être autorisées à utiliser ce produit 3 Éloignez les visiteurs et n autorisez JAMAIS les enfants dans la zone de travail AVERTISSEMENT RISQUE D OBJETS VOLANTS Portez toujours des lunettes de sécurité avec protections latérales lorsque le compresseur est utiliser Éteignez le compresseur et vidangez le réservoir d air avant d eff...

Страница 33: ...n canadienne de normalisation CSA AVERTISSEMENT Les moteurs l équipement électrique et les commandes peuvent provoquer des des étincelles qui enflammeront un gaz ou une vapeur inflammable Ne jamais utiliser ou réparer à proximité d un gaz ou d une vapeur inflammable N entreposez jamais de liquides ou de gaz inflammables à proximité du compresseur ATTENTION RISQUE DE BRÛLURES Les pièces du compress...

Страница 34: ...humidité ou de la dépressurisation du système de compresseur AVERTISSEMENT RISQUE D EXPLOSION OU D INCENDIE Ne faites jamaisfonctionnerlecompresseuràproximitédematériauxcombustibles d essence ou de vapeurs de solvants Si vous pulvérisez de matériaux inflammables placez le compresseur d air à au moins 50 m de la zone de pulvérisation Ne faites jamais fonctionner le compresseur à l intérieur ou dans...

Страница 35: ...t du compresseur doit être toujours dans une position stable N utilisez jamais le compresseur sur une surface inclinée une position sur le toit ou surélevée qui pourrait permettre à l unité de tomber ou de basculer Utilisez un tuyau d air supplémentaire pour les travaux en hauteur DANGER RISQUE DE CHOC ÉLECTRIQUE N utilisez jamais le compresseur sous la pluie ou dans des conditions humides Tout pr...

Страница 36: ...SECTION II INSTALLATION ...

Страница 37: ...upures de courant et les dommages permanents au moteur utilisation d une rallonge cordon annule la garantie INSTRUCTIONS DE MISE À LA TERRE 1 Ce produit est destiné à être utilisé sur une tension nominale d un circuit de 120 volts et a une prise de mise à la terre qui ressemble à la prise illustrée Fig 1 Assurez vous que le produit est connecté à une prise ayant la même configuration que la prise ...

Страница 38: ...t protecteur doit être évalué pour au moins l ampérage et la tension indiqués sur la plaque signalétique du moteur et respecter tous les codes électriques pour ce minimum 5 Utilisez un fusible à fusion lente ou un disjoncteur RALLONGES ÉLECTRIQUES Pour éviter une chute de tension une perte de puissance et une surchauffe du moteur utilisez un tuyau d air supplémentaire au lieu d une rallonge Une te...

Страница 39: ...SECTION III FONCTIONNEMENT ...

Страница 40: ...haud pendant l utilisation Pour éviter le risque de brûlures graves ne touchez jamais le tube de décharge CLAPET ANTI RETOUR Une valve unidirectionnelle qui permet à l air d entrer dans le réservoir mais empêche l air dans le réservoir de refluer dans la pompe du compresseur POIGNÉE Conçu pour déplacer le compresseur AVERTISSEMENT N utilisez jamais la poignée des unités à roues pour soulever compl...

Страница 41: ...ut de tuyau Ouvrir le régulateur Fig 3 Avec l interrupteur Fig 2 en position ON le compresseur pompe de l air dans le réservoir Il s éteint automatiquement lorsque l appareil atteint sa pression maximale préréglée En position OFF le pressostat ne peut pas fonctionner et le compresseur ne fonctionnera pas Assurez vous que l interrupteur Fig 2 est en position OFF lorsque brancher ou débrancher le co...

Страница 42: ...eumatique ou un pistolet à peinture 2 Tournez dans le sens des aiguilles d une montre pour augmenter la pression d air à la sortie Jusqu à ce que la pression désirée soit atteinte 3 Pour abaisser la pression d air à la sortie tournez dans le sens inverse des aiguilles d une montre 4 Tourner complètement dans le sens antihoraire pour couper le débit d air complètement puis poussez le bouton vers le...

Страница 43: ...SECTION IV ENTRETIEN ...

Страница 44: ...FF AVIS Placez l unité aussi loin que possible de la zone de pulvérisation car ceci limitera la sur pulvérisation qui pourrait obstruer le filtre PROTECTEUR DE SURCHARGE THERMIQUE ATTENTION Ce compresseur est équipé d une protection contre les surcharges thermiques à réarmement automatique qui éteindra le moteur en cas de surchauffe Si le protecteur de surcharge thermique ferme Le moteur fréquemme...

Страница 45: ...émarrera lorsqu il sera froid 5 Remplacer Le moteur ronronne mais ne fonctionne pas ou fonctionne très lentement 1 Clapet anti retour défectueux où déchargé 2 Mauvais contacts ligne tension basse 3 Moteur en court circuit ou bobinage moteur défectueux 1 Remplacer ou réparer 2 Vérifiez les connexions éliminez le bouchon d extension s il est utilisé vérifier le circuit avec un voltmètre 3 Remplacer ...

Страница 46: ...réservoir quand le compresseur éteint 1 Robinet de vidange desserré 2 Clapet anti retour qui fuit 3 Connexions desserrées au pressostat ou régulateur 1 Serrez 2 Démonter l ensemble du clapet anti retour nettoyer ou remplacer 3 Vérifiez toutes les connexions avec une solution d eau savonneuse et serrer Le compresseur fonctionne continuellement et le débit d air est plus faible supérieur à la normal...

Страница 47: ...r l interrupteur 2 Remplacez la soupape de sécurité par une pièce de rechange d origine Démarrage excessif et arrêt démarrage automatique Condensation excessive dans réservoir Vidanger plus souvent Fuite d air de déchargeur sur pressostat Clapet anti retour coincé en une position ouverte Retirer et remplacer le clapet anti retour DANGER Ne démontez pas le clapet anti retour avec l air dans le rése...

Страница 48: ...SECTION V PIÈCES ET SCHÉMAS ...

Страница 49: ...4G49X22 49 Cordon d alimentation 1 AC04G16X22 16 Vilebrequin 2 AC04G50X22 50 Interrupteur horizontal 1 AC04G17X22 17 Ventilateur 2 AC04G51X22 51 Tuyau en caoutchouc 1 AC04G18X22 18 Anneau élastique Ø14 2 AC04G52X22 52 Tube de déchargement 1 AC04G19X22 19 Couvercle 2 AC04G53X22 53 Tuyau de dégagement 1 AC04G20X22 20 Roulement 6006Z 2 AC04G54X22 54 Soupape de décharge 1 AC04G21X22 21 Stator 1 AC04G5...

Страница 50: ...50 AC04G X man SCHÉMAS FRANÇAIS ...

Страница 51: ......

Страница 52: ......

Отзывы: