PT 5201
PTV
Commands Explanation.
Operating Manual
Revision 2
9-7
OUTP:BB2:SCHP -160
set the ScHPhase for BB output 2 to -160deg
OUTP:BB2:SCHP?
response:
-160
•
OUTPut:BB1?
•
OUTPut:BB2?
•
OUTPut:BB3?
Command to display the complete settings of the three Black Burst output. The response
contains five fields:
<System>,<Field>,<Line>,<HTime>,<ScHPhase>
For an explanation of the response, see the commands:
OUTP:BBn:SYST
,
OUTP:BBn:DEL
and
OUTP:BBn:SCHP
, where n: 1-3
Example:
OUTP:BB1?
response: PAL,+2,+123,+12345.5,-160
•
OUTPut:TSGenerator:PATTern
Command to select the pattern of the SDI and Video outputs. Refer to chapter 10 PT5201
Signals for a description of the patterns available.
Not all the patterns are available in both systems. Trying to select a pattern, which is not
available in the active system, will result in an error, namely:
-200,”Execution error”
.
Example:
OUTP:TSG:PATT WIN100
set the pattern for a 100% window
OUTP:TSG:PATT?
response:
WIN100
•
OUTPut:TSGenerator:SYSTem
Command to select the system of the SDI and Video outputs. Systems available are
System
Description
PAL
PAL
NTSC
NTSC with setup
JNTSC
NTSC no setup
If the current pattern is invalid in the selected system, the pattern will be reset to a valid pattern
in the new system. See chapter 10, PT 5201 Signals, for the pattern-reset list.
Example:
OUTP:TSG:SYST PAL
set the system for PAL
OUTP:TSG:SYST?
response:
PAL
•
OUTPut:TSGenerator:DELay
Command to set the delay of the SDI and Video outputs.. The delay is defined by three
parameters
<Field>, <Line>,<HTime>
where
<Field>
sets the field offset,
<Line>
sets the line offset and
<HTime>
sets the
horizontal time in ns, i.e.
HTime(PAL) < 64000.0ns