Generator Settings:
The communication can be established by the PC Remote Control reading
the current settings of the unit. To open the communication click on the
desired functionally.
PC Settings:
The communication can be established by the PC Remote Control writing
its current/last settings. To open the communication click on the desired
functionally.
6.5.2.2.2
Disconnect
Disconnect is used to abort communication between the PC Remote Control program and a
connected unit before disconnecting the interface cable.
6.5.2.2.3
Demo Mode:
The Demo Mode is a way to demonstrate and operate the PC Remote Control offline. In this
mode it is not necessary to connect a PT 5201. Running the program in Demo mode give you
access to all the output features of the unit and access to store a set-up as a file. A set-up
saved as a file can be uploaded to the unit at any time, when a unit is connected.
6.5.2.3
Edit Menu
The menus under Edit all give direct access to the edit window to the given generator or access
to the calibration routine.
6.5.2.3.1
Genlock
The Genlock facility enables you to lock all outputs of the PT 5201 to a number of relevant video
and clock sources. The outputs of PT 5201 are locked to the source in frequency and phase.
System:
System refers to the list of relevant video and clock sources PT 5201 is
able to use as external reference.
PAL
and
NTSC
mode PT 5201 will expect a video signal of the given
system.
Internal mode
: all outputs of PT 5201 are locked to the internal high
stability TCXO oscillator.
10 MHz mode
: the source is expected to be a 10 MHz reference. The
internal oscillator will be locked to the reference and PT 5201 will act as in
Internal Mode. Due to the internal reference the timing feature is disabled.
When the reference source is valid and the oscillator circuit is in lock, the
”Genlocked” LED on the front panel, will be lit.
Timing:
All outputs of PT 5201 are timeable with reference to the Genlock video
signal. All outputs are timed in parallel in resolution of the individual output.
For timing details see Black Burst menu.
6.5.2.3.2
Black Burst
All three Black Burst outputs are digitally generated under the VariTime
TM
system and are
independent in timing and generation of TV system (NTSC/PAL).
The three Black Burst generators (BB1 – BB3) are identical in operation and functionality.