32 |
P a g e
4.2.3
Test 3 End Stops:
To test the endstops, first make sure none of the X, Y or Z axis endstops are
pressed. In the Repetier-Host G-Code command line run the
M119
command as
shown below. Note the result in the text log.
Reporting endstop status
x_min: open
x_max: open
y_min: open
y_max: open
z_min: open
z_max: open
All of the endstops should read
‘open’
, if not make sure none are pressed and check
wiring.