FloTech FT555 Automatic Truck Overfill System Tester
Page 26
10784PA Rev G
FT555 Truck Tester
Truck ID Module Test
The Truck ID Module will be tested and report the 12 digit serial
number stored inside the ID module. If there is no Truck ID
Module or the test fails the screen will show “TIM not found”
Step 1)
Connect API Extension Test Cable
Step 2)
Move the J-Slot thumb screws to the correct holes to match
the type of socket to be connected. Follow the “O” and “T”
markings on the plug body. Refer to Figure 2, on page 6.
Step 3)
Connect the FT555PA/PW Automatic Truck Tester to the
trailer socket.
Step 4)
Press and release the ON/OFF button to turn on the
FT555PA/PW Automatic Truck Tester. When “Press Key” screen
appears press and release the TEST SELECT button five times so
the “Truck ID Module Test” screen appears.
Step 5)
Press and release the GO button to start the test. When the
test is complete the screen will report the 12 digit serial number or
show “TIM not found”.
Step 6)
Press and release the TEST SELECT” button to move on
to a new test. Press and release the GO to restart the test, or press
and release the ON/OFF button to turn the tester off.
Truck ID Module Test
TIM Detected
Ser Num: 0000013338F6