PROGRAMMING
P-SERIES
Page 16 of 76
ECNT – “ELECTRONIC COUNTER”
This function is used to set the four (4) button code that will show historical cash sales, historical total
vends, historical product counts by selection, historical product counts that have occurred for prices, and
cabinet temperature when the vender is in sales mode. Press select button 1 to view the current four (4)
button code.
To change "ECNT" four button code:
At "ECNT" press select button 1, "####" (representing current four button code) will show on display
(“4231” is the factory default code). Press and hold select button 1 until the far left digit is replaced by an
“*” indicating it can be changed. Press the select button desired for the first digit of the code. The next
digit will be replaced by an “*” press the select button desired for that digit of the code. Continue this
process until all 4 digits are set. After the last digit is entered the display will return to “ECNT”.
Note: The four-button code must use select buttons 1 through 9 only.
Enter the four button code while in sales mode to view the data. Once entered the listed data is available
from the front of the vender:
Press select button 1: Show historical cash sales.
Press select button 2: Show historical total vends.
Press select button 3: Show historical product counts by selection.
Press select button 4: Show historical cash sales by selection
Press select button 5: Show temperature inside the cabinet.
Press select button 6: Returns to sales idle mode (sales vender operation).
Note: There is a thirty (30) second time-out that will return the vender to sales mode if no select buttons
are pressed.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
LIM – LIMITED ACCESS
This function is used to program the vender to use the Limited Access Features. To move to Secondary
Price Menu, press & hold select buttons 1 & 2 simultaneously, to enter the sub-menu press select button
1. The following are sub-menus of the Limited Access Menu: (LAOS) "Selects", "Days”, (STR1) “Start 1”,
(STP1) “Stop 1”, (STR2) “Start 2”, (STP2) “Stop 2” , and (RTN) “Return”.
(LAOS) – LIMITED ACCESS ON SELECTION
This function is used to set selection(s), which, will be limited during certain periods of the day.
To view the selection setting condition, press select button 1. The display will show "Selects##
#”(## #) where ## is the selection number and # is a “0” OR “1” depending on whether the
selection is enabled (1) or disabled (0). Press and hold select button 1 to toggle between “0” &
“1. Press select buttons 1 & 2 simultaneously to scroll through all available select buttons,
“NONE”, “ALL”, and “RTN”. Pressing select button 1 when “ALL” is” displayed will cause the
display to change to “ON” when all selections have been enabled. Pressing select button 1 when
“NONE” is” displayed will cause the display to change to “OFF” when all selections have been
disabled. Press select button 1 at the “RTN” prompt returns to “Selects”.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
Содержание DN552P-7
Страница 9: ...PROGRAMMING P SERIES Page 9 of 76 Factory Default Setting Selection Column 1 1 2 1 3 2 4 3 5 4 6 5 7 6...
Страница 32: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 32 of 76 ALL BILLS ARE REJECTED...
Страница 33: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 33 of 76 INCORRECT CHANGE DISPENSED...
Страница 34: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 34 of 76 SELECTION WILL NOT VEND...
Страница 35: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 35 of 76 ICE FROST ON EVAPORATOR COMPRESSOR RUNS CONTINUOUSLY...
Страница 36: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 36 of 76 COMPRESSOR WILL NOT START...
Страница 37: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 37 of 76 MACHINE NOT COOLING...
Страница 39: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 39 of 76 LIGHTS ARE NOT ON...
Страница 41: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 41 of 76 SOLD OUT...
Страница 42: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 42 of 76 THE DISPLAY IS DEAD...
Страница 43: ...TROUBLESHOOTING FLOWCHARTS P SERIES Page 43 of 76 CAN T READ THE DISPLAY...
Страница 44: ...WIRING DIAGRAMS AND SCHEMATICS P SERIES Page 44 of 76 7 Select 6 Column...
Страница 45: ...WIRING DIAGRAMS AND SCHEMATICS P SERIES Page 45 of 76 Refrigeration Circuit Diagrams...
Страница 46: ...PARTS LIST P SERIES Page 46 of 76 MAIN DOOR EXTERIOR...
Страница 47: ...PARTS LIST P SERIES Page 47 of 76 MAIN DOOR EXTERIOR...
Страница 50: ...PARTS LIST P SERIES Page 50 of 76...
Страница 55: ...PARTS LIST P SERIES Page 55 of 76 INNER DOOR 6 7 10 4 2 9 3 5 1 8...
Страница 66: ...PARTS LIST P SERIES Page 66 of 76 EVAPORATOR FAN ASSEMBLY 4B 3 2 7 4A 9 5 6 21 22 23 24...
Страница 72: ...PARTS LIST P SERIES Page 72 of 76 SCREWS NUTS...
Страница 74: ...PARTS LIST P SERIES Page 74 of 76 WASHERS BOLTS MISC HARDWARE...