Step 3. PLATE REMOVAL:
Using the plate lifter, remove the plate and
bushing from the grinder unit. It is
necessary to lift while pulling on the bushing.
Do not use screwdrivers or other tools to pry
the plate from the grinder unit.
Step 4. KNIFEHOLDER REMOVAL:
Remove the knifeholder from the face of the
grinder. The knife inserts are sharp, so wear
appropriate gloves.
Step 5. REMOVE SPRINGS: Remove the
Belleville springs, 2 each. Some pins have a
spacer collar behind the Belleville springs, if
this collar is used, remove it also.
Step 6. REMOVE THE
CENTERING PIN
Do not loose the pin key when you are
removing the pin!
Step 7. REMOVE THE FEEDSCREW
FROM THE GRINDER UNIT.
We recommend using our Model FSP2006
feedscrew puller to remove the feedscrew (see
next page). If you do not have a FSP2006
feedscrew puller, we recommend using a
worm cart, chain hoist, or other suitable
lifting device.
The feedscrews are heavy, about 250 pounds.
Do not attempt to remove the feedscrew by
hand.
The feedscrew needs to be handled carefully
so that the outside diameter is kept free of
nicks and burrs. Be careful, the feedscrew
has sharp corners that can cut, the cupping is
sharp!
Wear appropriate safety equipemnt and
remember to always
"Work Safely".