XW562K
5/6
14
DIMENSIONS
15
CONNECTIONS
16
DEFAULT SETTING VALUES
Label Name
Range
Default
REGULATION
Set1 Set point1
LS÷US
40,0
Set2 Set point2
LS2÷US2
40,0
Hy
Differential for set1
0,1÷25,5 °C
2,0
Hy2 Differential for set2
0,1÷25,5 °C
2,0
LS
Minimum set point1
-50,0°C÷SET1
-40,0
US
Maximum set point1
SET1 ÷ 110°C
50,0
LS2 Minimum set point2
-50,0°C÷SET2
-40,0
US2 Maximum set point2
SET2 ÷ 110°C
60,0
OdS Outputs activation delay at start up
0÷255 min.
0
AC
Anti-short cycle delay
0÷30 min.
3
AC1 Second compressor start delay
0÷255s
10
Ac2
Second compressor start delay progr.2
0 ÷ 255s
10
on
Minimum time a compressor remains on (it’s used both
for compr. 1 and 2)
0÷30 minutes
5
Mon
Maximum time compressor is continuously on
(permanent run monitoring)
0÷120min
0
cP2
Compressor 2 enabled with program 2
y = yES; n = no
yES
COn Compressor ON time with faulty probe
0÷255 min.
15
COF Compressor OFF time with faulty probe
0÷255 min.
30
S2F Second set point enabling
yES÷no
yES
DISPLAY
CF
Temperature measurement unit
°C ÷ °F
°C
Label Name
Range
Default
rES
Resolution (integer/decimal point)
in ÷ dE
dE
dot
Display offset,
program 1
0÷25.5 °C
2.0
do2
Display offset, program 2
0÷25.5 °C
2.0
dHy Display histeresys
0÷25.5 °C
2.0
DEFROST
MdF Defrost key enabling
yES= enabled
no= disabled
YES
tdF
Defrost type
rE, in
rE
EdF Kind of defrost
rtc, in
rtc
dtE
Defrost termination temperature (1°Evaporator)
-50,0÷110°C
8,0
dt2
Defrost termination temperature for program 2
-50.0°C o –58°F ÷ 110°C o
230°F
8,0
IdF
Interval between defrost cycles
1÷120h
12
id2
Interval between defrost cycles for the program 2
1 ÷ 120 hours
12
Mtd
(Maximum) length for 1° defrost
0÷255 min.
30
Mt2
(Maximum) length of defrost for the program 2
0 ÷ 255 minuts
30
dFd
Display during defrost
dEG; dEF
dEF
dSd
Defrost delay
0÷255min
0
Fdt
Draining time
0÷60 min.
0
dPO First defrost after start up
n ÷ y
no
FANS
CFE Condenser fan working during defrost
yES÷no
YES
FnC Fans operating mode
C-n, C-y, O-n, O-y
o-n
Fc2
Fans operating mode with program 2
c_n
/
c_Y
/
o_n
/
o_Y
o-n
Fnd
Fans delay after defrost
0÷255 min.
0
FSt
Fans stop temperature
-50,0÷110°C
2.0
ALARMS
ALU MAXIMUM temperature alarm for set1
-50,0÷110°C
50.0
Au2 MAXIMUM temperature alarm for set2
-50,0÷110°C
50.0
ALd Temperature alarm delay
0÷255 min.
15
dAO Delay of temperature alarm at start up
0 ÷ 23h 50 min.
1,3
tBA
Alarm relay silencing
yES÷no
no
oAP Alarm relay polarity
oP, cL
oP
ArE
Digital input 1 actives the alarm relay
yES÷no
no
ANALOGUE INPUTS
Ot
Thermostat probe calibration
-12,0÷12,0°C
0.0
P2P Evaporator probe presence
no ÷ yES
yES
OE
Evaporator probe calibration
-12,0÷12,0°C
0.0
P3P Second evaporator probe presence
no ÷ yES
no
O3
Second evaporator probe calibration
-12,0÷12,0°C
0.0
DIGITAL INPUTS
I1P
Door switch polarity
CL÷OP
cL
I2P
Pressure switch digital input polarity
CL÷OP
oP
I3P
Defrost end digital input polarity
CL÷OP
oP
dId
Digital input alarm delay
0÷255 min.
0
Label Name
Range
Default
TIME AND WEEKLY HOLIDAYS
Hur
Current hour
0 ÷ 23
- - -
Min
Current minute
0 ÷ 59
- - -
dAY
Current day
Sun ÷ SAt
- - -
Hd1
First weekly holiday
Sun÷ SAt – nu
nu
Hd2
Second weekly holiday
Sun÷ SAt – nu
nu
Hd3
Third weekly holiday
Sun÷ SAt – nu
nu
DEFROST TIMES
Ld1
1
st
workdays defrost start
0 ÷ 23h 50 min. - nu
3,0
Ld2
2
nd
workdays defrost start
0 ÷ 23h 50 min. - nu
nu
Ld3
3
rd
workdays defrost start
0 ÷ 23h 50 min. - nu
nu
Ld4
4
th
workdays defrost start
0 ÷ 23h 50 min. - nu
nu
Ld5
5
th
workdays defrost start
0 ÷ 23h 50 min. - nu
nu
Ld6
6
th
workdays defrost start
0 ÷ 23h 50 min. - nu
nu
Ld7
7
th
workdays defrost start
0 ÷ 23h 50 min. - nu
nu
Ld8
8
th
workdays defrost start
0 ÷ 23h 50 min. - nu
nu
Sd1
1
st
holiday defrost start
0 ÷ 23h 50 min. - nu
nu
Sd2
2
nd
holiday defrost start
0 ÷ 23h 50 min. - nu
nu
Sd3
3
rd
holiday defrost start
0 ÷ 23h 50 min. - nu
nu
Sd4
4
th
holiday defrost start
0 ÷ 23h 50 min. - nu
nu
Sd5
5
th
holiday defrost start
0 ÷ 23h 50 min. - nu
nu
Sd6
6
th
holiday defrost start
0 ÷ 23h 50 min. - nu
nu
Sd7
7
th
holiday defrost start
0 ÷ 23h 50 min. - nu
nu
Sd8
8
th
holiday defrost start
0 ÷ 23h 50 min. - nu
nu
2L1
1st workdays defrost start program 2
0 ÷ 23h 50 min. - nu
7,0
2L2
2nd workdays defrost start program 2
0 ÷ 23h 50 min. - nu
19,0
2L3
3rd workdays defrost start program 2
0 ÷ 23h 50 min. - nu
nu
2L4
4th workdays defrost start program 2
0 ÷ 23h 50 min. - nu
nu
2L5
5th workdays defrost start program 2
0 ÷ 23h 50 min. - nu
nu
2L6
6th workdays defrost start program 2
0 ÷ 23h 50 min. - nu
nu
2L7
7th workdays defrost start program 2
0 ÷ 23h 50 min. - nu
nu
2L8
8th workdays defrost start program 2
0 ÷ 23h 50 min. - nu
nu
2S1
1st holiday defrost start program 2
0 ÷ 23h 50 min. - nu
nu
2S2
2nd holiday defrost start program 2
0 ÷ 23h 50 min. - nu
nu
2S3
3rd holiday defrost start program 2
0 ÷ 23h 50 min. - nu
nu
2S4
4th holiday defrost start program 2
0 ÷ 23h 50 min. - nu
nu