dIXEL
Installing and Operating Instructions
R1.0 1592007271
1592007271 XR80C-D GB r1.0 20.05.2005.doc
XR80C – XR80D
4/4
13.4
XR80D: 20A COMPRESSOR
Power
Supply
230Vac
11 12
3 4
Line
8(3)A/250Vac
20(8)A/250Vac
15 16 17 18 19
Comp
n.c.
HO
T K
EY
24Vac/dc supply
: connect to the terminals 11 and 12.
120Vac supply
: connect to the terminals 11 and 12.
230Vac supply
: connect to the terminals 11 and 12.
14.
DEFAULT SETTING VALUES
Label
Name
Range
Values
Set
Set point
LS÷US
2.0
Hy
Differential
0,1
÷
25.5°C/ 1
÷
255°F
2.0
LS
Minimum set point
-50°C
÷
SET/-58°F
÷
SET
-30.0
US
Maximum set point
SET
÷
150°C/ SET
÷
302°F
20.0
Ot
Thermostat probe calibration
-12
÷
12°C / -120
÷
120°F
0.0
OdS
Outputs delay at start up
0÷255 min
0
AC
Anti-short cycle delay
0
÷
50 min
1
COn
Compressor ON time with faulty probe
0
÷
255 min
15
COF
Compressor OFF time with faulty probe
0
÷
255 min
30
CF
Temperature measurement unit
°C
÷
°F
°C
rES
Resolution
in
÷
dE
dE
AgC
Agitator configuration
EL=with compressor;
in=independent
EL
tIC
Resolution for the Agt parameter
nP=minutes; Pb=seconds
nP
IAg
Interval between agitation cycle
1÷120min
15
Agt
Length for agitation cycle
0÷255min
3
APO
First agitation cycle after start up
y=immediately; n=after IAG
n
ALc
Temperat. alarms configuration
rE; Ab
Ab
ALU
MAXIMUM temperature alarm
ALL
÷
150.0°C; ALL ÷302°F
100
ALL
Minimum temperature alarm
-50.0°C
÷
ALU/ -58°F
÷
ALU
-50.0
ALd
Temperature alarm delay
0
÷
255 min
15
dAo
Delay of temperature alarm at start up
0
÷
23h e 50’
1.3
PbC
Probe selection
Ptc
÷
ntc
ntc/Ptc
rEL
Software release
--
1.2
Ptb
Map code
--
--
Hidden parameters
Dixell S.p.A. Z.I. Via dell’Industria, 27
32010 Pieve d’Alpago (BL) ITALY
tel. +39 - 0437 - 98 33 - fax +39 - 0437 - 98 93 13