Installing and Operating Instructions

R1.0 1592007271

1592007271 XR80C-D GB r1.0 20.05.2005.doc

XR80C – XR80D

4/4

13.4

 

XR80D: 20A COMPRESSOR

Power 

Supply

230Vac

11 12

 

 3 4

Line

8(3)A/250Vac

20(8)A/250Vac

 15 16 17 18 19 

Comp

n.c.

HO

T K

EY

24Vac/dc supply

: connect to the terminals 11 and 12.

120Vac supply

: connect to the terminals 11 and 12.

230Vac supply

: connect to the terminals 11 and 12.

14.

 

DEFAULT SETTING VALUES

Label

Name

Range

Values

Set

Set point

LS÷US

2.0

Hy

Differential

0,1

÷

25.5°C/ 1

÷

 255°F

2.0

LS

Minimum set point

-50°C

÷

SET/-58°F

÷

SET

-30.0

US

Maximum set point

SET

÷

150°C/ SET 

÷

 302°F

20.0

Ot

Thermostat probe calibration

-12

÷

 12°C /  -120 

÷

 120°F

0.0

OdS

Outputs delay at start up

0÷255 min

0

AC

Anti-short cycle delay

÷

 50 min

1

COn

Compressor ON time with faulty probe

÷

 255 min

15

COF

Compressor OFF time with faulty probe

÷

 255 min

30

CF

Temperature measurement unit

°C 

÷

 °F

°C

rES

Resolution

in 

÷

 dE

dE

AgC

Agitator configuration

EL=with compressor;

in=independent

EL

tIC

Resolution for the Agt parameter

nP=minutes; Pb=seconds

nP

IAg

Interval between agitation cycle

1÷120min

15

Agt

Length for agitation cycle

0÷255min

3

APO

First agitation cycle after start up

y=immediately; n=after IAG

n

ALc

Temperat. alarms configuration

rE; Ab

Ab

ALU

MAXIMUM temperature alarm

ALL

÷

150.0°C; ALL ÷302°F

100

ALL

Minimum temperature alarm

-50.0°C

÷

ALU/ -58°F 

÷

 ALU

-50.0

ALd

Temperature alarm delay

÷

 255 min

15

dAo

Delay of temperature alarm at start up

÷

 23h e 50’

1.3

PbC

Probe selection

Ptc 

÷

 ntc

ntc/Ptc

rEL

Software release

--

1.2

Ptb

Map code

--

--

Hidden parameters

Dixell S.p.A.  Z.I. Via dell’Industria, 27
32010 Pieve d’Alpago (BL) ITALY
tel. +39 - 0437 - 98 33  -  fax +39 - 0437 - 98 93 13

E-mail: [email protected] - http://www.dixell.com

Содержание XR80C

Страница 1: ...al parameters that can be easily programmed through the keypad 3 CONTROLLING LOADS 3 1 THE COMPRESSOR The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point va...

Страница 2: ...le value for the set point US Maximum set point SET 150 C SET 302 F Set the maximum acceptable value for set point Ot Thermostat probe calibration 12 0 12 0 C 120 120 F allows the adjustment of possible offset of the thermostat probe OdS Outputs activation delay at start up 0 255min This function is enabled at the initial start up of the instrument and inhibits any output activation for the period...

Страница 3: ...emp alarm Output unchanged LA Minimum temp alarm Output unchanged 11 1 ALARM EE The instrument is provided with an internal check verifying memory integrity Alarm EE flashes when a failure in the internal memory is detected In such case call the service 11 2 ALARM RECOVERY Probe alarm P1 start some seconds after the fault in the related probe it automatically stops some seconds after the probe res...

Страница 4: ...ON time with faulty probe 0 255 min 15 COF Compressor OFF time with faulty probe 0 255 min 30 CF Temperature measurement unit C F C rES Resolution in dE dE AgC Agitator configuration EL with compressor in independent EL tIC Resolution for the Agt parameter nP minutes Pb seconds nP IAg Interval between agitation cycle 1 120min 15 Agt Length for agitation cycle 0 255min 3 APO First agitation cycle a...

Отзывы: