1592009037 XW270-271L GB r1.0 15.12.2004.doc

                           

;:/  ;:/

2/4

TO START A MANUAL DEFROST

1.

Push the DEF key for more than 2 seconds and a manual defrost will start.

TO ENTER IN PARAMETERS LIST “PR1”
To enter the parameter list “Pr1” (user accessible parameters) operate as follows:

1. Enter the Programming mode by pressing the Set and DOWN key for few seconds

(

 and 

 

start blinking).

2.

The instrument will show the first parameter present in “Pr1”

TO ENTER IN PARAMETERS LIST “PR2”
To access parameters in “Pr2”:
1.

 

Enter the “Pr1” level.

2.

 

Select “Pr2” parameter and press the “SET” key.

3.

 

The “PAS” flashing message is displayed, shortly followed by “0 - -” with a flashing zero.

4.

 

Use 

9

9

 or 

8

8

 to input the security code in the flashing digit; confirm the figure by pressing “SET”. The

security code is “321“.

5.

 

If the security code is correct the access to “Pr2” is enabled by pressing “SET” on the last digit.

Another possibility is the following: after switching ON the instrument the user can push Set and DOWN keys
within 30 seconds.

NOTE: each parameter in “Pr2” can be removed or put into “Pr1” (user level) by pressing “SET” + 

8

8

. When a

parameter is present in “Pr1” LED 

 is on.

HOW TO CHANGE THE PARAMETER VALUE
1.

 

Enter the Programming mode.

2.

 

Select the required parameter with 

9

9

 or 

8

8

.

3.

 

Press the “SET” key to display its value (

 and 

 LED starts blinking).

4.

 

Use 

9

9

 or 

8

8

 to change its value.

5.

 

Press “SET” to store the new value and move to the following parameter.

To exit: Press SET + UP or wait 15s without pressing a key.
NOTE: the new programming is stored even when the procedure is exited by waiting the time-out.

HOW TO LOCK THE KEYBOARD

1. 

Keep the 

9

9

 and 

8

8

 keys pressed together for more than 3 s the 

9

9

 and 

8

8

 keys.

2. 

The “POF” message will be displayed and the keyboard is locked. At this point it is only
possible the viewing of the set point or the MAX o Min temperature stored and to switch ON
and OFF the light, the auxiliary output and the instrument.

TO UNLOCK THE KEYBOARD

Keep the 

9

9

 and 

8

8

 keys pressed together for more than 3s.

ON/OFF FUNCTION

By pushing the ON/OFF key, the instrument shows “OFF” for 5 sec. and the ON/OFF LED is
switched ON.
During the OFF status, all the relays are switched OFF and the regulations are stopped; if a
monitoring system is connected, it does not record the instrument data and alarms.
N.B. During the OFF status the Light and AUX buttons are active.

TO SEE THE PROBE VALUES

1.

Enter in “Pr2” level.

2.

Select “Prd” parameter with 

9

9

 or 

8

8

.

3.

Press the “SET” key to display “Pb1” label alternate with Pb1 value.

4.

Use 

9

9

and 

8

8

 keys to display the other probe values.

5.

Press “SET” to move to the following parameter.

PARAMETER LIST

REGULATION

Hy

Differential: (0,1÷25,5°C; 1÷45°F): Intervention differential for set point, always positive. Compressor Cut
IN is Set Point Plus Differential (Hy). Compressor Cut OUT is when the temperature reaches the set point.

LS

Minimum set point limit: (-50,0°C

÷

SET; -58°F÷SET) Sets the minimum acceptable value for the set

point.

US

Maximum set point limit: (SET

÷

110°C; SET÷230°F) Set the maximum acceptable value for set point.

OdS Outputs activation delay at start up: (0÷255 min) This function is enabled at the initial start up of the

instrument and inhibits any output activation for the period of time set in the parameter. (AUX and Light can
work)

AC

Anti-short cycle delay: (0÷30 min) interval between the compressor stop and the following restart.

CCt Thermostat override: (0min ÷23h 50min) allows to set the length of the continuous cycle. Can be used, for

instance, when the room is filled with new products.

Con Compressor ON time with faulty probe: (0÷255 min) time during which the compressor is active in case

of faulty thermostat probe. With COn=0 compressor is always OFF.

COF Compressor OFF time with faulty probe: (0÷255 min) time during which the compressor is off in case of

faulty thermostat probe. With COF=0 compressor is always active.

DISPLAY

CF

Temperature measurement unit: °C = Celsius; °F = Fahrenheit . When the measurement unit is changed
the SET point and the values  of the regulation parameters have to be modified

rES Resolution (for °C): (in = 1°C; de = 0,1°C) allows decimal point display.

de = 0,1°C
in = 1 °C

Lod Local display : select which probe is displayed by the instrument:

P1 = Thermostat probe
P2 = Evaporator probe
P3 = auxiliary probe
1r2 = difference between P1 and P2 (P1-P2)

Red Remote display : select which probe is displayed by the remote display (XW-REP)

P1 = Thermostat probe

P2 = Evaporator probe
P3 = auxiliary probe
1r2 = difference between P1 and P2 (P1-P2)

DEFROST

tdF Defrost 

type:

rE = electrical heater (Compressor OFF)
rT = thermostat defrost. During the defrost time “MdF”, the heater switches On and OFF depending on the
evaporator temperature and “dtE” value.
in = hot gas (Compressor and defrost relays ON)

EdF Defrost mode: 

in = interval mode. The defrost starts when the time “Idf” is expired.
Sd = Smartfrost mode. The time IdF (interval between defrosts) is increased only when the compressor is
running (even non consecutively) and only if the evaporator temperature is less than the value in "SdF” (set
point for SMARTFROST).

SdF Set point for SMARTFROST: (-30

÷

30 °C/ -22

÷

86 °F) evaporator temperature which allows the IdF

counting (interval between defrosts) in SMARTFROST mode.

 dtE  Defrost termination temperature: (-50,0÷110,0°C; -58÷230°F) (Enabled only when the evaporator probe

is present) sets the temperature measured by the evaporator probe which causes the end of defrost.

IdF

Interval between defrosts: (1÷120h) Determines the time interval between the beginning of two defrost
cycles.

MdF  (Maximum) duration of defrost: (0÷255 min) When P2P = n, no evaporator probe, it sets the defrost

duration, when P2P = y, defrost end based on temperature, it sets the maximum length for defrost.

dFd  Display during defrost:

rt = real temperature;
it = temperature reading at the defrost start;
Set = set point;
dEF = “dEF” label;
dEG = “dEG” label;

dAd  Defrost display time out: (0

÷

255 min) Sets the maximum time between the end of defrost and the

restarting of the real room temperature display.

Fdt Drain down time: (0÷60 min.) time interval between reaching defrost termination temperature and the

restoring of the control’s normal operation. This time allows the evaporator to eliminate water drops that
might have formed due to defrost.

dPO First defrost after start-up:

= Immediately;
n = after the IdF time

dAF  Defrost delay after fast freezing: (0min÷23h 50min)  after a Fast Freezing cycle, the first defrost will be

delayed for this time.

FANS

FnC Fan operating mode:

C-n = running with the compressor, OFF during the defrost;
C-y = running with the compressor, ON during the defrost;
O-n = continuous mode, OFF during the defrost;
O-y = continuous mode, ON during the defrost;

Fnd Fan delay after defrost: (0÷255 min) The time interval between the defrost end and evaporator fans start.
FSt Fan stop temperature: (-50÷110°C; -58÷230°F) setting of temperature, detected by evaporator probe,

above which the fan is always OFF.

ALARMS

ALC Temperature alarm configuration

rE = High and Low alarms related to Set Point
Ab = High and low alarms related to the absolute temperature.

ALU High temperature alarm setting:

ALC= rE, 0 

÷

 50°C or 90°F

ALC= Ab, ALL 

÷

 110°C or 230°F

when this temperature is reached and after the ALd delay time the HA alarm is enabled.

ALL Low temperature alarm setting:

ALC = rE , 0 

÷

 50 °C or 90°F

ALC = Ab , - 50°C or -58°F 

÷

 ALU

when this temperature is reached and after the ALd delay time, the LA alarm is enabled,.

AFH Temperature alarm and fan differential: (0,1÷25,5°C; 1÷45°F) Intervention differential for temperature

alarm set point and fan regulation set point, always positive.

ALd Temperature alarm delay: (0÷255 min) time interval between the detection of an alarm condition and the

corresponding alarm signalling.

dAO Delay of temperature alarm at start-up: (0min÷23h 50min) time interval between the detection of the

temperature alarm condition after the instrument power on and the alarm signalling.

EdA  Alarm delay at the end of defrost: (0

÷

255 min) Time interval between the detection of the temperature

alarm condition at the end of defrost and the alarm signalling.

dot  Delay of temperature alarm after closing the door : (0

÷

255 min) Time delay to signal the temperature

alarm condition after closing the door.

doA  Open door alarm delay:(0÷255 min) delay between the detection of the open door condition and its alarm

signalling: the flashing message “dA” is displayed.

tbA  Buzzer and alarm relay silencing: by pushing one of the keypad buttons.

n= Only the Buzzer is silenced;
y= Buzzer and relay are silenced.

nPS  Pressure switch number: (0 

÷

15) Number of activation of the pressure switch, during the “did” interval,

before signalling the alarm event (I2F= PAL).

PROBE INPUTS

Ot

Thermostat probe calibration: (-12.0

÷

12.0°C/ -21

÷

21°F) allows to adjust possible offset of the

thermostat probe.

OE   Evaporator  probe  calibration:  (-12.0

÷

12.0°C/ -21

÷

21°F) allows to adjust possible offsets of the

evaporator probe.

O3

Auxiliary probe calibration: (-12.0

÷

12.0°C/ -21

÷

21°F) allows to adjust possible offsets of the evaporator

probe.

P2P Evaporator probe presence:

n= not present: the defrost stops only by time; y= present: the defrost stops by temperature and time.

P3P Auxiliary probe presence: n= not present; y= present.
HES Temperature increase during the Energy Saving cycle : (-30,0°C 

÷

 30,0°C / -22÷86°F) sets the

increasing value of the set point during the Energy Saving cycle.

DIGITAL INPUTS

odc Compressor and fan status when open door:

no = normal;
Fan = Fan OFF;
CPr = Compressor OFF;
F_C = Compressor and fan OFF.

I1P

Door switch input polarity:
CL
 : the digital input is activated by closing the contact;

Содержание Wing XW270L

Страница 1: ... 3 4 CONTROL OF EVAPORATOR FANS The fan control mode is selected by means of the FnC parameter FnC C n fans will switch ON and OFF with the compressor and not run during defrost FnC C y fans will run continuously but not during defrost After defrost there is a timed fan delay allowing for drip time set by means of the Fnd parameter FnC O n fans will switch ON and OFF with the compressor and run du...

Страница 2: ...pending on the evaporator temperature and dtE value in hot gas Compressor and defrost relays ON EdF Defrost mode in interval mode The defrost starts when the time Idf is expired Sd Smartfrost mode The time IdF interval between defrosts is increased only when the compressor is running even non consecutively and only if the evaporator temperature is less than the value in SdF set point for SMARTFROS...

Страница 3: ... The digital inputs polarity depends on I1P and I2P parameters CL the digital input is activated by closing the contact OP the digital input is activated by opening the contact INSTALLATION AND MOUNTING Instruments XW270L XW271L shall be mounted on vertical panel in a 150x31 mm hole and fixed using two screws 3 x 2mm To obtain an IP65 protection grade use the front panel rubber gasket mod RG L The...

Страница 4: ...mmon Door switch Digital inp Def Display Room ALARM AUX Def Comp Fan Light Line N eutral 20A 250Vac MAX 20A 8A 250Vac 16A 250Vac 8A 250Vac 8A 250Vac 16A 250Vac DEFAULT SETTING VALUES Label Name Range Default Level REGULATION C F XW270L XW271L Set Set point LS US 5 Pr1 Pr1 Hy Differential 0 1 25 5 C 1 45 F 2 Pr1 Pr1 LS Minimum set point 50 0 C SET 58 F SET 30 Pr2 Pr2 US Maximum set point SET 110 C ...

Отзывы: