If air volume is low and the contaminant is not being captured, adjustments will need to be 

made. Consult your DIVERSITECH Distributor. 

Apply compressed air to the manifold. Turn the reverse jet pulse control on. Apply power to 

other auxiliary equipment as required. 

COMMENTS REGARDING FILTER DIFFERENTIAL PRESSURE DURING OPERATION

Depending on dust loading and Air-To-Cloth Ratio, reaching equilibrium of filter differential 

pressure will vary from a few hours to many weeks. Low dust loading will normally develop 2-

3”w.g. with normal loading 3-6”w.g. and with high loading 6 - 8”w.g. 

Low dust loading typically shows a steady level of differential pressure with very little 

fluctuations once equilibrium is reached. By contrast, heavy loading can produce significant 

“Ups and Downs” in operating differential pressure.  

Do make immediate “Off-Time” time reductions on the timer board dial if significant increases 

in operating differential pressure are discovered. However, if differential pressure drops, do 

not be too quick to increase “Off-Time”, and then only in small steps.

NOTE: 

A critical step in start up is to reach an acceptable operating equilibrium point. This must 

be reached gradually in order to not damage the filters by blinding. While achieving 

equilibrium, you want to clean the filters more often than required instead of not often 

enough. Gradually and tentatively increase valve “Off Time” until equilibrium is reached. 

Also, making notes and recording the results will help gage the effectiveness of various 

DIVERSITECH filters and filter pretreatment. Should questions arise contact your 

DIVERSITECH distributor. 

Shutdown 

Shutdown consists of shutting down the blower motor. With systems that include a “Cycle 

Down” feature the reverse jet pulse cleaning will be activated. This will clean the filter 

cartridges while the unit is off line, for a preset amount of time. Once the cleaning cycle is 

complete the collector is ready to be energized when needed.

 

Caution: 

Off line cleaning can cause pressure waves to feed back through the inlet of 

the collector and the attached duct work. Precautions might be needed to 

prevent dusting. 

Maintenance Safety 

Care with the design of DIVERSITECH collectors has minimized safety hazards for the 

maintenance and production personnel. 

Caution:  

Personnel involved with the DIVERSITECH collector must be familiar with 

the operation and the information in this manual. 

Содержание WB-4000-D

Страница 1: ...ion Maintenance Manual WB 4000 D Visit our Website for more information on this product www diversitech ca 1200 55th Avenue Montreal Quebec H8T 3J8 Tel 1 800 361 3733 Fax 1 514 631 9480 info diversite...

Страница 2: ...all potential hazards related to dust control equipment or systems Therefore it is imperative that the application and use of this equipment be discussed with an DIVERSITECH distributor and that this...

Страница 3: ...NSTALLATION CONSIDERATIONS 4 INSPECTION 4 MECHANICAL INSTALLATION 4 COMPRESSED AIR SUPPLY 5 ELECTRICAL CONTROLS 5 PRE START UP 7 FILTER INSTALLATION 7 START UP 7 SHUT DOWN 8 MAINTENANCE SAFETY 8 MAINT...

Страница 4: ...h as Weld fume and grinding dust The cleaned air is then returned to the work space to eliminate the need to exhaust treated air Once the unit is mounted connection of electrical power and compressed...

Страница 5: ...ooth Remove and RETAIN the access cover from the desired side of the master booth The slave booth ships with only a cover on the back If the slave is to be positioned back to back with the master remo...

Страница 6: ...or from the blower door of the collector The blower motor will need to be energized through a motor starter with over load protection The electrical components must be sized and selected in accordance...

Страница 7: ...tart up Be sure the horizontal flange around the venturi is clean With care not to damage filter cartridge place gasket side down on flange Rotate filter slightly to assure no binding and proper locat...

Страница 8: ...s to reach an acceptable operating equilibrium point This must be reached gradually in order to not damage the filters by blinding While achieving equilibrium you want to clean the filters more often...

Страница 9: ...ntial Pressure during Operation at the beginning of page 7 2 Assure the collected dust is removed from the dust storage container as required 3 Assure the predetermined cleaning schedule is proper to...

Страница 10: ...n the system b Unscrew the bonnet bolts and remove the bonnet c Inspect the diaphragm for dust and damage Remove dust with water and replace damaged parts with diaphragm repair kit for 1 or 1 5 valves...

Страница 11: ...ion s of motor wiring Rewire motor circuit with proper wire size Dust Discharge from Collector outlet a Filter cartridges not properly installed b Damaged filter cartridge c Damaged filter cap s d Wor...

Страница 12: ...ng Increase available air volume Refer to page 5 Increase air pressure to Maximum of 100 PSI Eliminate source of contamination and purge compressed air line Confirm input power to timer board or contr...

Страница 13: ...each Plate Filter Cap with gasket 1222 X each T Handle Filter Clamp 1224 X each T Handle Access Door Latch 1023 X each Gasket Door Seal 1214 X feet Valve 1 5 Double Diaphragm 1221 X each Motor XX HP 3...

Страница 14: ...n misuse or use above rated capacities FREIGHT CLAIMS Shipments must be inspected upon arrival All Diversitech units are sold ex plant Therefore it is the receiver s responsibility to file any freight...

Отзывы: