Page 7 of 17
4.5 Reverse Pulse Filter Cleaning System
The downdraft table is equipped with a reverse pulse automatic filter cleaning system. This system is controlled by a PC
board inside the control box (Labelled “AVP-Z”). Changing the dip switch settings on the AVP-Z board, allows you to
control:
1.
Pulsing online or offline
2.
Number of pulses
3.
Pulse duration
Solenoid operated air valves discharge large blasts of air through the filter cartridges thus dislodging particles embedded in
the filter media. The particles fall into a dust drawer located below the cartridge. The angled v-shaped baffles above the
drawer prevent the dust from re-entering the cabinet when the machine is turned on.
Neglecting to pulse the filter regularly will reduce filter life.
Factory Setting
DIP SWITCH #
FACTORY SETTING
This factory setting allows for online & offline
pulsing. 1 x 0.5 second air blast every 45 seconds,
while online, and 20 x 0.5 second air blast when
offline.
1
ON
2
OFF
3
ON
4
OFF
Recommended for Aluminum Dust
DIP SWITCH #
FACTORY SETTING
This factory setting allows for only offline pulsing,
20 x 0.5 second air blast each time the machine is
switched off.
1
OFF
2
OFF
3
ON
4
OFF
Custom Application Settings
DIP SWITCH #
PURPOSE
LEFT
RIGHT
1
Mode
Online & Offline
Offline Only
2
Duration
0.5 second
1 second
3
Number of Pulses
4
# OF PULSES
DIP SWITCH #3
DIP SWITCH #4
5
OFF
OFF
10
OFF
ON
20
ON
OFF
30
ON
ON
Содержание DD-3X4