background image

Page 1 of 17 

SECTION 1 – SAFETY PRECAUTIONS OF FUME & DUST EXTRACTION/COLLECTION 

 

 

READ 

BEFORE 

USE

 

This manual contains specific cautionary statements related to worker safety.  To 
protect yourself and others, read this manual thoroughly and follow as directed 
before use.  Not all hazards of fume & dust control are listed in this manual, and no 
hazards related to welding, cutting, grinding, painting, deburring or other 
applications are listed.  Consult a qualified safety professional  

 

DO  

NOT 

USE 

Do not use this equipment: 

 

To extract smoke or fumes above 180°F / 82°C. 

 

To extract combustible dusts, liquid vapors, aggressive fumes such as acids. 

 

If the power cord has been damaged or ground (third prong) removed. 

 

Without a filter. 

 

1.1 Symbols 

This manual uses 
several symbols to 
highlight specific 
hazards.  Be familiar 
with these symbols 
and when you see 
them in this manual, 
read adjoining 
warning text to avoid 
the hazard. 
 

 

 

 

 

WARNING! 

DANGER! 

ELECTRIC 

SHOCK 

MOVING 

PARTS 

HOT 

PARTS 

1.2 User Responsibility 

 

Improper use can be hazardous. 

 

It is your responsibility to follow all applicable ANSI, OSHA, UL, CSA, National & Local Fire Codes, and other 
regulatory guidelines covering the safe use of equipment that extracts fumes, collects dusts, and exhausts filtered 
air either indoors or outdoors.   

 

Before use, inspect the unit for damage and verify it is working properly.  

 

Only qualified persons should install, operate, maintain, or repair this unit. 

 

Do not modify or repair the unit with parts or accessories not supplied by the manufacturer. 

 

Consult filter manufacturer’s instructions for filter use and reuse, including instructions for cleaning. 

1.2 Fume Extraction Hazards 

 

Breathing smoke, fumes, or dusts produced in applications such as welding, cutting, grinding, painting, deburring 
are hazardous to user’s health.  Proper ventilation or use of well maintained fume extraction and/or dust collection 
equipment helps the user avoid these hazards. 

 

Breathable contaminants may not be visible or have an odor.   

 

Stop operation and leave the area immediately if 1) breathing becomes difficult, 2) experience dizziness, 3) 
impaired vision, 4) or eye/nose/mouth irritation. 

1.3 Dust Collection Hazards 

 

Dusts from many welding, cutting, grinding, painting, or deburring applications can be combustible.   

 

Do not use or install equipment where any potential for combustible fumes or dusts are present, until a qualified 
person has indicated it is safe to do so. 

 

Never use or install equipment where the potential for combustible fumes or dusts are present without a 
fire/explosion protection system. 

 

If you are unsure if the product you purchased is correct for your application, call Diversi-Tech at 1-800-361-3733. 

Содержание DD-3X4

Страница 1: ...es DD 4X4 DD 4X6 DD 4X8 DD 5X10 Multi Workstation Tables READ AND SAVE THESE INSTRUCTIONS Visit our Website for more information on this product www diversitech ca 2500 Alphonse Gariepy Montreal Quebe...

Страница 2: ...ation 5 3 5 Preparing Unit for Operation 5 SECTION 4 OPERATION 6 4 1 To Operate Safely 6 4 2 Controls 6 4 3 Pre Use Checklist 6 4 4 Principles of Operation 6 4 5 Reverse Pulse Filter Cleaning System 7...

Страница 3: ...tered air either indoors or outdoors Before use inspect the unit for damage and verify it is working properly Only qualified persons should install operate maintain or repair this unit Do not modify o...

Страница 4: ...Page 2 of 17 SECTION 2 SPECIFICATIONS 2 1 Model Configurations Description Open Works surface Side Back Walls Clean Air Workstation DD 3X4 DD 3X6 DD 3X8 DD 4X4 DD 4X6 DD 4X8 DD 5X10...

Страница 5: ...Filter Part Filter Filter Filter Qty Type Number Size Area Efficiency Filters sq ft Required DD 3X4 Nanofiber S 3X4 0024 16 w flange 140 99 99 0 5 micron 2 DD 3X6 Nanofiber S 3X6 0024 16 w flange 140...

Страница 6: ...48 36 14 6 x 2 DD 4X6 10 x 2 73 68 5 49 72 48 36 14 6 x 2 DD 4X8 10 x 2 97 68 5 49 96 48 36 14 6 x 2 DD 5X10 10 x 2 121 68 5 31 120 30 36 34 12 x 2 DD 3X4 EO 10 x 2 49 68 5 49 48 48 36 14 12 DD 3X6 E...

Страница 7: ...or rotation in the right direction o Correct direction of BLOWER WHEEL ROTATION CLOCKWISE Compressed Air o Supply 80 90 PSI of CLEAN DRY compressed air to the bulkhead bushing on the side of the unit...

Страница 8: ...e unit level stable and that nothing is obstructing the extraction path o LISTEN Does the motor and suction sound smooth and within expected volumes o FEEL Place your hand on top of the unit and sense...

Страница 9: ...above the drawer prevent the dust from re entering the cabinet when the machine is turned on Neglecting to pulse the filter regularly will reduce filter life Factory Setting DIP SWITCH FACTORY SETTIN...

Страница 10: ...ing filter inspection The input power to this unit is high voltage and touching any live electrical parts can cause fatal shocks or severe burns Do not touch live electrical parts Keep away from all m...

Страница 11: ...Operating Hours Inspect Clean Cabinet Remove and wipe down dust drawer baffle trays and metal mesh prefilters depositing accumulated particulate in appropriate waste container Refer to local regulati...

Страница 12: ...nge when pulsed regularly is 6 18 months As part of routine maintenance it is important to visually inspect the filter Replace the filter if you see 1 Overloading or accumulation of particles 2 Rips t...

Страница 13: ...Page 11 of 17 5 5 Troubleshooting Procedure...

Страница 14: ...er ELECTRIC SHOCK HAZARD Disconnect power before performing any maintenance on unit including filter inspection The input power to this unit is high voltage and touching any live electrical parts can...

Страница 15: ...photocopied or otherwise reproduced as needed for management of maintenance records MANUFACTURER DIVERSITECH INC MODEL NO FRED SERIAL NO SERVICE LOCATION CONTROL NO Date Description of Service Servic...

Страница 16: ...10 0HP Aluminum Blower Wheel backward inclined S WHEL 0012 15 0HP Aluminum Blower Wheel backward inclined S 184T 050T2 5 0HP TEFC MOTOR 230 3 60 S 184T 050T4 5 0HP TEFC MOTOR 460 3 60 S 184T 050T5 5...

Страница 17: ...14 Hinged left right side walls fixed back 4 steel frame w clear lexan insert A X SMW 01 Side walls middle seperator powder coated mild steel A X SMW 11 Side walls middle seperator 4 steel frame with...

Страница 18: ...Page 16 of 17 NOTES...

Страница 19: ...Page 17 of 17 NOTES...

Страница 20: ...reight claims for obvious or concealed damages which developed in transit from Montreal to your location or when drop shipped RETURN MATERIAL POLICY Prior to the return of material for whatever reason...

Отзывы: