![Dive Gear Express XTRA Second Stage Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/dive-gear-express/xtra-second-stage/xtra-second-stage_service-manual_2510479021.webp)
12. Slide the complete assembly into the Case (11). Ensure that the lever fits between the tabs in the Case
and is seated, as shown. Ensure that the Lever (20) moves freely. Place the Oring (09) on the threaded end
of the Spindle (19). – Fig. 31. Place the Retaining Nut (08) on the Spindle and thread it on. Tighten with the
11/16
ths
wrench. Fig. 32.
Do not overtighten as this can crack the case!
Fig. 31 Fig. 32
13. Turn the Case so that the Adjusting Spring (34) can be seen. – Fig.31. Install the Rubber Cap (35) onto the
Adjusting Screw (30) to cover the spring. Fig.32
Fig. 33 Fig. 34
14. Using the InLine Adjusting Tool, while depressing the Lever (20), turn the orifice so that the Lever (20) is
even with the face of the Case (11).
Only turn the orifice when the lever is depressed to avoid cutting the LP
seat!
This is the preliminary adjustment of the cracking pressure. The final adjustment will be made with the
tool when the second stage is pressurized. – Fig. 35
Fig. 35