DR-109 characteristics. 

Power supply ............................................... 88 to 264VAC, 47 to 63 Hz. 
Consumption ................................................ 35VA 
Consumption at minimum brightness  ....... 13,2VA. 
Display .......................................................... 4 digits 7segments 57mm  two central dots. 
 ....................................................................... Red LED. Visibility 30 meters. 
Display HH:MM:SS....................................... 6 digits 7segments 57mm 2x two central dots. 
 ....................................................................... Red LED.Visibility 30 meters. 
Environmental conditions .......................... Operating temperature: -10 to 60ºC. 
 ....................................................................... Storage temperature: -20ºC to 70ºC 
 ....................................................................... Relative humidity:  5-95% non condensation. 
 ....................................................................... Maximum environmental lighting: 1000 lux. 
 ....................................................................... Protection IP 41 or IP65. 
Weight ........................................................... .4,5 Kg. 

Timed power-up of the display 

This display operates in two operation modes: full-operative mode and power-saving mode. In power-

saving mode the display does not show the time in order to save energy when the display is not needed. If the 
power-saving  function  is  not  needed  and  the  display  should  always  powered  up,  the  both  power-up  and 
power-down times must be the same. 

Parameters of the display 

There  are  three  keys  on  the  back  side  of  the  display.  These  keys  are  used  to  access  and  navigate 

through the menu of the display. The identification of the keys is 

 
   

 

 

 

Advance key. Access parameter/switch digits 

  
  

 

Enter key. Validate parameter. 

  
  

Increase key. Increase the value of the digit 

  
 

Changing the time 

In  case  the  user  wants  to  change  the  time,  the  Advance  key  must  be  pressed  for  three  seconds. 

Using the Advance (to change digit) and the Increase (to increase the value of the digit) keys the present time 
can be changed. To leave  the menu, press the Advance key past the digit corresponding to the  units of the 
minute. If the time has changed, the seconds are changed to 0 when leaving the menu. Take in consideration 
that  the  time  displayed  in  the  menu  must  be  UTC  time.  In  case  the  display  is  configured  to  sync  using  the 
GPS or the SNTP connection, the time inserted by the user will be overwritten. 

 

 

Содержание DR-109

Страница 1: ...of the display see GPS option in this manual If the display includes option NE Ethernet connectivity this display hosts a web site where the user can see the status of the display and configure it Thi...

Страница 2: ...7 to 63 Hz The power supply conductor section will be in line with consumption and the ground conductor will be a minimum section of 1 5m The power supply connector for 220VAC has 4 contacts and is si...

Страница 3: ...the display should always powered up the both power up and power down times must be the same Parameters of the display There are three keys on the back side of the display These keys are used to acce...

Страница 4: ...guration press the Enter key Navigation here is the same as before Once set the month press the Enter key to switch to year configuration Navigation here is the same as before Once set the year press...

Страница 5: ...er 6 Display power down time This parameter configures the time the display changes from full operative mode to power save mode When accessing in this parameter the hour the display changes to power s...

Страница 6: ...s 8 bits Odd 1 17 9600 Bauds 8 bits Odd 1 18 19200 Bauds 8 bits Odd 1 19 4800 Bauds 7 bits No parity 2 20 9600 Bauds 7 bits No parity 2 21 19200 Bauds 7 bits No parity 2 22 4800 Bauds 8 bits No parity...

Страница 7: ...splays that include GPS sync with the GPS standard signal This allows a better time sync without Ethernet connectivity GPS antenna includes a magnet that can be fixed to a ferric surface This antenna...

Страница 8: ...or the default IP of the display is out of the IP range of you LAN it is recommended to use the PC program Display Discoverer downloadable from the web www lartet com In this program the displays conn...

Страница 9: ...1706K39C Page 9 of 26 Tip the new IP and click OK There will appear a message in the main window with the message sent to the display...

Страница 10: ...1706K39C Page 10 of 26 After some seconds click the Refresh button The display appears with the new IP Click the display IP to open a new tab in the browser The main page of the web server is shown...

Страница 11: ...splay which usually is in a difficult access point The web page can be accessed remotely if the router is correctly redirected See Annex 2 View the web page remotely for more information The main page...

Страница 12: ...in the field The second tab allows configuring the network parameters of the display including the IP address DNS etc The display can use DHCP to get these parameters on its own The name of the displ...

Страница 13: ...ly When clicking the button validate the system saves the changes and reboots If the parameters are put manually the work is finished On the other side the display may have changed the IP address This...

Страница 14: ...tions parameters seen from the webpage the user must configure Other parameters don t care Networks with one display One display Ethernet network Ethernet network Configure net parameters Sync no Time...

Страница 15: ...oth are configured the same way Ethernet network Ethernet network Ethernet network Ethernet network Configure net parameters Sync SNTP Write the server addres in the field SNTP server Configure net pa...

Страница 16: ...others sync with the server display Ethernet network Ethernet network Client display Configure net parameters Sync Display Ethernet Write the display server addres in the field Client display Configur...

Страница 17: ...TP server and serves the time to the other displays Ethernet network Ethernet network Client display Configure net parameters Sync Display Ethernet Write the display server addres in the field Client...

Страница 18: ...er o a cloud SNTP server All displays update from the SNTP server specified Ethernet network Ethernet network Configure net parameters Sync SNTP Write the server addres in the field Configure net para...

Страница 19: ...Frame This frame only includes the code This does not send any data Code End of block ACII P H Hexa 50h 48h Response frame Code Data End of block Code Day Month Year Space Hour Minute Second End of bl...

Страница 20: ...ion must be the same for all RS 485 network There are many configurations possible only with RS 485 or combining different options this displays offer The following networks are the most usual but the...

Страница 21: ...39C Page 21 of 26 Sync through a display with GPS RS 485 network RS 485 network Client display Sync Parameter 4 2 3 RS 485 Client display Sync Parameter 4 2 3 RS 485 Server display Sync Parameter 4 2...

Страница 22: ...d to a SNTP server Ethernet network Ethernet network RS 485 network RS 485 network Client display Sync Parameter 4 2 3 RS 485 Client display Sync Parameter 4 2 3 RS 485 Server display Configure net pa...

Страница 23: ...Display time request P H Time programming F H Display time request Frame This frame only includes the code This does not send any data Code Address End of block ACII P H H L Hexa 50h 48h Example Requ...

Страница 24: ...nd End of block ASCII F H H L DD MM AA HH MM SS Hexa 46h 48h 20h Example Send 13 16 00 16 05 2013 to the display at address 03 Code Address Data End of block Code Address Day Month Year Space Hour Min...

Страница 25: ...nal Port The same port as the start port Internal Start Port The port the user enters wants to enter the display In this case the port is 80 which is the standard web page access IP address The LAN IP...

Страница 26: ...le responsibility that the aforementioned product complies with the following European directives Directive LVD 2006 95 CEE Low Voltage Directive Standard UNE EN61010 1 Security in electric equipment...

Отзывы: