![Ditch Witch SK752 Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/ditch-witch/sk752/sk752_operators-manual_2510014064.webp)
SK752 Operator’s Manual
Service - 63
Startup/10 Hour
Check Hydraulic Fluid Level
Check hydraulic fluid level at startup and every
10 hours. Maintain fluid level at halfway point on
sight glass (2), when engine is off, cylinders are
fully retracted, and fluid is cool. If low, add THF at
fill (1).
Check Brake Operation
Check brake operation at startup and every 10
hours or more often when conditions warrant..
•
Ensure parking brake pin (shown) moves
freely allowing brake to be engaged and
disengaged.
•
Clean mud and debris from area around pin.
Check Lug Nut Torque
Check lug nut torque at 10 hours, 50 hours and
every 200 hours thereafter. Tighten to 88-95 ft•lb
(108-129 N•m) as needed.
IMPORTANT:
Engine must be running to
check brake operation.
t35om013w.eps
1
2
t35om014w.eps
t35om036w.eps
Содержание SK752
Страница 1: ...SK752 Operator s Manual 053 2859 Issue 2 0 Original Instruction...
Страница 11: ...Contents 10 SK752 Operator s Manual...
Страница 21: ...Safety 20 SK752 Operator s Manual Machine Safety Alerts...
Страница 31: ...Controls 30 SK752 Operator s Manual Attachment Plate...
Страница 41: ...Prepare 40 SK752 Operator s Manual Connect Attachment...
Страница 47: ...Drive 46 SK752 Operator s Manual Shut Down...
Страница 55: ...Transport 54 SK752 Operator s Manual Retrieve...
Страница 86: ......
Страница 87: ......
Страница 88: ...SK752 Operator s Manual Service Record 87 Service Record Service Performed Date Hours...
Страница 89: ...Service Record 88 SK752 Operator s Manual Service Performed Date Hours...