![Ditch Witch SK752 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/ditch-witch/sk752/sk752_operators-manual_2510014014.webp)
SK752 Operator’s Manual
Safety - 13
Emergency Procedures
Emergency Procedures
Before operating any equipment, review emergency procedures and check that all safety precautions have
been taken.
Electric Strike Description
When working near electric cables, remember the following:
•
Electricity follows all paths to ground, not just path of least resistance.
•
Pipes, hoses, and cables will conduct electricity back to all equipment.
•
Low voltage current can injure or kill. Many work-related electrocutions result from contact with less
than 440 volts.
Most electric strikes are not noticeable, but indications of a strike include:
•
power outage
•
smoke
•
explosion
•
popping noises
•
arcing electricity
If any of these occur, assume an electric strike has occurred.
Jobsite hazards could cause death or serious injury. Use
correct equipment and work methods. Use and maintain proper safety
equipment.
EMERGENCY SHUTDOWN
- Turn ignition switch to stop position or push remote engine stop button (if
equipped).
Electric shock will cause death or serious injury. Stay
away.
274-049
Содержание SK752
Страница 1: ...SK752 Operator s Manual 053 2859 Issue 2 0 Original Instruction...
Страница 11: ...Contents 10 SK752 Operator s Manual...
Страница 21: ...Safety 20 SK752 Operator s Manual Machine Safety Alerts...
Страница 31: ...Controls 30 SK752 Operator s Manual Attachment Plate...
Страница 41: ...Prepare 40 SK752 Operator s Manual Connect Attachment...
Страница 47: ...Drive 46 SK752 Operator s Manual Shut Down...
Страница 55: ...Transport 54 SK752 Operator s Manual Retrieve...
Страница 86: ......
Страница 87: ......
Страница 88: ...SK752 Operator s Manual Service Record 87 Service Record Service Performed Date Hours...
Страница 89: ...Service Record 88 SK752 Operator s Manual Service Performed Date Hours...