distyNotruf
pro
, Operating instructions
Factory setting
The following operating procedure is performed to reset to delivery status factory setting
(default), which will work only when the device is subscribed.
•
Set
distyNotruf
to CS. Red LED illuminates as confirmation and acoustic “beep”
signal is heard.
•
Press the alarm key latest after 5 seconds and hold for 10 seconds
•
Green LED illuminates
•
Let go of alarm key before LED switches off (2 seconds time)
•
A 450 Hz - tone is heard and red LED illuminates
•
Remove
distyNotruf
from charging cable
•
distyNotruf
switches to power down (every function is switched off)
•
programmed alarm numbers are not deleted
NOTE:
The correct function of the alarm numbers has
to be proofed and adjusted if necessary.
A failed alarm can cause big costs and
trouble!
Page 8 of 33