236613ACA
SJ3013 & SJ3014 micro
38
Section 4 – Inspections Before Operation
Function Tests
4.3-14 Do a test of the brakes
IMPORTANT
The brakes engage instantly when you release the
function-enable switch. This causes the MEWP to
stop immediately.
1.
Make sure the path of intended motion is clear.
2.
Push the
drive
button
2
.
3.
Squeeze and hold the
function-enable
switch.
4.
Drive the MEWP forward and then rearward.
Release the
controller handle.
▪
Result:
The MEWP stops. Do not operate the
MEWP if the MEWP pulls to one side while it
stops. A service technician must do a check
on the brake adjustments.
5.
Drive the MEWP forward and then rearward.
Release the
function-enable
switch only.
▪
Result:
The MEWP stops. Do not operate the
MEWP if it pulls to one side while it stops. A
service technician must do a check on the
brake adjustments.
4.3-15 Do a test of the platform raise and
lower functions
WARNING
Look for overhead obstructions or other possible
hazards around the MEWP when you raise the
platform. Do not lower the platform unless the area
below is clear of personnel and obstructions. If
you do not obey, there is a risk of death or serious
injury.
1.
Push the
lift/lower
button
6
.
2.
Squeeze and hold the
function-enable
switch.
3.
Pull
the
controller handle
to raise the platform
by approximately 0.5 m (20 in).
▪
Result:
The platform rises.
4.
Squeeze and hold the
function-enable
switch.
5.
Push
the
controller handle
to fully lower the
platform.
▪
Result:
The platform fully lowers.
4.3-16 Do a test of the horn
1.
Push the
horn
button
7
.
▪
Result:
The horn makes a sound.
4
5
1
7
3
6
2
8
To
order go
to
Discount-Equipment.com