SW
M
IRD
LNB 1
LN
B
1
89
OFF
0
0 MA
13.2v
Accutrac Pro Meter
ASL Peaking
SWiM Integrated LNB Peaking:
DO NOT CONNECT ANY IRD to the SWiM Integrated LNB BEFORE OR DURING THE
PEAKING PROCESS
1)
Be sure the mast is plumb and the foot plate is secure to an approved
mounting surface.
2)
Obtain the azimuth, elevation and tilt settings from the DIRECTV
receiver.
3)
Preset the antenna tilt and elevation to the settings obtained.
4)
Apply power to the SWiM Integrated LNB using the power inserter as the
diagram outlines.
(When power is applied, and before any receivers are
connected, the SWiM Integrated LNB will enter a diagnostic mode that
is required for the alignment procedure.)
5)
Connect the Accutrac Pro meter LNB 1 to the 101 port of the ASL unit.
Press the on /menu button.
6)
Adjust the antenna’s azimuth to obtain a signal lock and peak the signal
level on your bar graph. If you cannot obtain a lock, just peak the signal
level and try to obtain the lock in the next step.
7)
Now adjust the elevation to obtain the peak signal level and a signal
lock.
8)
At this point, you should be ROUGHLY aligned to 101 West.
You can now follow the KaKu dithering process as outlined in the
KaKu Dithering procedures
Note: You will have to disconnect the cable from the 101° port on the ASL and connect to
the 119° port on the ASL during the tilt adjustment step of the dithering process