SWM
IRD
DIRECTV SWM 101
S llllllllllllllllllllllllllllllllllllllllllllll··· 211
Q llllllllllllllllllllllllllllllllllllllllllll…. 95%
Found
DIRECTV SWM 119
S llllllllllllllllllllllllllllllll………….191
Q llllllllllllllllllllllllllllllllllllllllllll…. 98%
Found
BirDog Meter
ASL Peaking
SWiM Integrated LNB Peaking:
DO NOT CONNECT ANY IRD to the SWiM Integrated LNB BEFORE OR DURING THE
PEAKING PROCESS
1)
Be sure the mast is plumb and the foot plate is secure to an approved
mounting surface.
2)
Obtain the azimuth, elevation and tilt settings from the DIRECTV
receiver.
3)
Preset the antenna tilt and elevation to the settings obtained.
4)
Apply power to the SWiM Integrated LNB using the power inserter as
the diagram outlines.
(When power is applied, and before any
receivers are connected, the SWiM Integrated LNB will enter a
diagnostic mode that is required for the alignment procedure.)
5)
Connect the Birdog meter to the 101 port of the ASL unit. Press the
arrow button to select
DIRECTV SWiM 101
6)
Adjust the antenna’s azimuth to obtain a signal lock and peak the
signal level on your bar graph. If you cannot obtain a lock, just peak the
signal level and try to obtain the lock in the next step.
7)
Now adjust the elevation to obtain the peak signal level and a signal
lock.
8)
At this point, you should be ROUGHLY aligned to 101 West.
You can now follow the KaKu dithering process as outlined in the
KaKu Dithering procedures
Note: You will have to disconnect the cable from the 101° port on the ASL and connect
to the 119° port on the ASL during the tilt adjustment step of the dithering process
OUT
INPUT
OFF
ON
Software updates can be found at the following link
http://www.birdog.tv/
Download the following files
DIRECTV SWM 101
DIRECTV SWM 119
DTV Ka/Ku 3g 119 west
DTV Ka/Ku 3g 101 west
Notice
With the BIRDOG meter turned off, press and hold
the up arrow button to get to the backend menu.
Press the down arrow, scroll through the Menu until
you see the
“
RF
”
option
Change the
“RF” option to “ Linear
” by using the
right arrow
Press the down arrow, scroll through the Menu until
you see the
“
BER
”
option
Change the “
BER option to “Log” by using the right
arrow key
Press the up arrow until you see “Exit” then press