MI6 Manual - Version 1.1
CHAPTER 4: Operation
Signal Input / Output
BNC OUT / IN
2 x BNC socket (coaxial)
OUT:
MADI output (64 ch), connect for MADI
output signal here.
IN:
MADI input (64 ch), connect MADI input
signal here.
SFP
1 x SFP cage*
Insert SFP module here and connect MADI
input/output
SC OUT / IN
2 x SC socket (optical)
OUT:
MADI output (64 ch), connect for MADI
output signal here.
IN:
MADI input (64 ch), connect MADI input
signal here.
AES I/O | LINE OUT
1 x DSUB-9 connector (female)
Connect DSUB-9 adaptor here for
XLR connection of AES I/O and Line Out.
*
empty cage, module not included in delivery
All MADI outputs carry the signal of the selected MADI input.
Power Fail Through (PFT)
The coaxial I/O maintains the signal transmission from BNC input to BNC output in
case of a power loss.
WARNING!
Only use the original adaptor or observe correct pin assignment - see “Appendix A:
Wiring AES I/O, Line Out” on page 30.
1
2
3
4
1
2
3
4