© 2004 Directed Electronics, Inc. Vista, CA
4
49
9
lloonngg tteerrm
m eevveenntt hhiissttoorryy
The system stores the last two full triggers in memory. These are not erasable. Each time the unit sees a full trigger,
the older of the two triggers in memory will be replaced by the new trigger. To access long term event history:
1.
With the ignition off, press and H
HO
OLLD
D the Valet®/Program switch.
2.
Turn on the ignition.
3.
Release the Valet®/Program switch.
4.
Press and release the Valet®/Program switch within 5 seconds. The LED will flash in groups
indicating the last two zones that triggered the unit for one minute or until the ignition
is turned off.
N
NO
OTTEE:: The Warn Away triggers are not stored to memory and will not be reported.
LLEED
D FFLLA
ASSH
HEESS
SSH
HU
UTTD
DO
OW
WN
N M
MO
OD
DEE
One
Timed out
Two
Over-rev shutdown
Three
Low or no RPM
Four
Transmitter shutdown (or optional push-button)
Six
(-) Shutdown (H3/3 GRAY) or (+) Shutdown (H3/4 BROWN)
Seven
(-) Neutral safety shutdown (H3/6 BLACK/WHITE)
Eight
Wait-to-start timed out
Содержание 871XP
Страница 55: ...2004 Directed Electronics Inc Vista CA 5 55 5...