GB
Malfunction
Possible cause
Elimination
The pump is not
discharging any liquid,
the motor is not
running.
No current.
Please use a device complying with GS
(German technical supervisory authority)
to check for the presence of voltage
(safety information to be observed!).
Please verify.
Thermal motor protection feature has
triggered.
Separate the pump from the electrical
mains, allow the system to cool down,
eliminate cause.
The capacitor is defective.
Please contact the customer service
department.
The motor shaft is jamming.
Check the cause, eliminate the reason for
the jamming of the pump.
The motor is running,
but the pump is not
discharging any liquid.
The pump housing is not filled with
liquid.
Fill the pump housing with liquid (please
refer to ”Putting into operation” section).
Air penetrates into the intake line.
Check to make sure that :
a.) the connection points of the intake
line are tight.
b.) the inlet opening of the intake line
including the check valve (non-return
valve) are immersed into the liquids
being discharged.
c.) the check valve (non-return valve)
with the filter is tight and not jammed.
d.) no siphons (i.e. permanently liquid-
filled loops), kinks, counter-slopes or
narrow spots are present along the
intake lines.
Suction height and/or discharge height
too great.
Change the arrangement of the
installation so that the suction height
and/or discharge height will not exceed
the max. value.
The pump stops after a
short time of operation
because the thermal
motor protection
feature has triggered.
The electrical supply does not
correspond to the information given on
the type plate.
Please use a device complying with GS
(German technical supervisory authority)
to check the voltage of the lines of the
connection cord (safety information to
be observed!).
Pump or intake line are blocked
by solids.
Remove possible congestion.
Liquid is too viscous.
Pump may not be suitable for this liquid.
If feasible, the liquid should be thinned.
Temperature of liquid or environment
is too high.
Make sure that the temperature of
the liquid being pumped and the
environment do not exceed the max.
admissible values.
The pump does not
reach the desired
pressure.
Refer to section 2.2.
Refer to section 2.2.
Worn pump wheel.
Please contact the customer service
department.