GB
2. TECHNICAL DATA
Model
GC-800I-24H5
Mains voltage / Frequency
(V / Hz)
230/50
Nominal performance (Watts)
800
Protection type (IP)
44
Suction port
F26/34 (1")
Pressure port
F26/34 (1")
Max. flow rate (Qmax)
(1)
(l/h)
3300
Max. pressure
(3)
(bar)
4,6
HMT
Max. delivery height
(Hmax)
(1)
(m)
46
HA
Max. suction height (m)
9
Vessel material
STEEL
Tank volume (l)
24
Max. size of the solids being
pumped (mm)
3
Min. fluid temperature (°C)
5
Max. fluid temperature
(Tmax) (°C)
35
Length of connection cable (m)
1,5
Cable type
H05RN-F
Weight (net) (kg)
11,8
Guaranteed sound power level
(LWA)
(2)
(dB)
81
Measured sound power level
(LWA)
(2)
(dB)
77
ACS
NO
Dimensions (L x D x H) (mm)
50x290x580
1) The values were determined with free, unreduced in- an outlet.
2) Noise emission values obtained according to the EN 12639
regulation. Measurement method according to EN ISO 3744.
Preset of the pressure switch
Cut-in pressure (bar)
2
Cut-out pressure (bar)
3,5
3) The theoretically achievable pressure of the pump unit of the
domestic water supply can reach the value specified under
“Max pressure”. Consult a qualified specialist, to adapt the
pressure circuit to your requirements if necessary, see also
the chapter “Setting the pressure switch”.
3. RANGE OF USE
The typical areas of use of booster sets include:
Automatic domestic water supply with grey water
(according to the versions) from wells and cisterns,
automated irrigation of gardens and garden beds and
sprinkling, pressure boosting within the domestic
water supply system. The device is not suited for
use in swimming pools. This product is intended for
private use in the home area and not for commercial
or industrial purposes or for continuous circulating.
The pump is not suited to discharge
saltwater, faeces, inflammable, etching,
explosive or other hazardous liquids.
Please observe the max. and min.
temperatures of the liquids to be discharged stated
in the technical data.
4. SCOPE OF DELIVERY
The scope of the delivery of this product includes :
one booster set with a connection cord, one oper-
ating manual.
Please verify that the scope of delivery is complete.
Depending on the purpose of the application, addi-
tional accessories may be necessary (see Chapter
7, 8 and 9).
If possible, keep the packing until the warranty
period has expired. Please dispose of the packing
materials in an environmental-friendly manner.
5. INSTALLATION
5.1. GENERAL INSTALLATION INFORMATION
During the entire process of installation, the
device must not be connected to the elec-
trical mains.
The pump should be installed in a dry place
with an ambient temperature not to exceed
40 °C and not to fall below 5 °C. The pump
and the entire connection system have to be protect-
ed from frost and other climatic influences.
When installing the device, please make
sure that the motor is sufficiently ventilated.
All connection lines have to be perfectly tight since
leaking lines may affect the performance of the
pump and cause considerable damage. Therefore,
please use Teflon tape to seal the contact surfaces
between the threaded sections of the lines and
the connection with the pump. This use of sealing
material such as Teflon tape is the only way to ensure
an airtight assembly.
When tightening threaded connections, please do
not apply excessive force which may cause damage.
When laying the connection pipes, you should make
sure that the pump is not exposed to any form of
weight, vibration or tension. Moreover, the connection
lines must not contain any kinks or an adverse slope.
Please observe the illustrations, too, which are
contained in the present operating instructions. The
numeric and other details included in brackets below
refer to these illustrations.