background image

 

 

  

Controller Unit: 
 

Antenna matches are stored into a bank of 85 memory locations. Each memory location is 
a fraction of an amateur band. Refer to the technical section for the fractional segments for 
each band. As shown in the picture below, the upper line of the LCD shows the actual 
memory location chosen (lower edge frequency 1840 kHz) with its span (20 kHz). The 
control settings for this frequency are shown in the lower line of the LCD.  In the Automatic 
Mode the memory location and its stored settings is selected by the transmitted input 
frequency. The input frequency is obtained from an RF probe. The memory location 
contents can be erased by a push button on the back of the controller. 
 
 
The controller contains 3 rotary encoders that control the tuner elements TRX, L, and ANT.  
TRX controls the Input Capacitance, L controls the Inductance and ANT the output 
capacitance values. The lower line on the display shows these values.

 

 
A manual selector switch is provided for memory selection in the Manual mode.  
 
 

Controller Unit 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 
 
 
 

LED is lighted when 
Power Supply operates 
and Power Switch is off 

Power  Switch 

L values switchable in 31 
steps. 

Never switch with full 
poser!

 Max. switching 

power 300W 

Control of the variable 
output capacitor. 1 step 
corresponds to 0.9° tuning 
angel.  Max. 200 steps 

Memory:

 Read out of the stored settings in 

either automatic or manual mode. 

Tune: 

Matching the antenna with the rotary 

switches Input, L and ANT 

Mem In:

 By pressing this momentary switch 

down the indicated control settings are 
stored into memory

Input Capacitors 
switchable in 256 steps, 
17pF each. Steps appear 
upon LC Display following 
“Txxx” 

In „Manual“ mode all 
memory locations can be 
selected 

LC Display 
The upper row shows the 
actual memory location 
(lower edge frequency 
with the span) 
The lower row shows the 
actual control settings for 
the antenna

 

Mode switch 
„Manual“ or 
„Automatic“ 
or “Thru” 

 

Yellow LED lights, as long 
as tuning proceeds. Don’t 
key the transmitter during 
this time 

 

 
 
                                                                                                 Page 3 of 24

Содержание AT- 615B

Страница 1: ...alanced Antenna Tuner Model AT 615B Short Form Manual 10 2010 Dipl Ing Klaus Bemmerer RF Communication Electronics Niendorf Middeldor 11 23769 Fehmarn GERMANY Phone 49 4371 869145 Fax 49 4371 869154 www hamware de eMail service hamware de ...

Страница 2: ...it can be used in either automatic or manual mode The matching circuit consists of a remotely tuned balanced π circuit The balun is placed at the input of the tuner The Output capacitor is a stepper motor controlled High Voltage variable capacitor The Control Cabinet contains the tuning controls memory location selection Automatic or Manual switching and a display that indicates the memory locatio...

Страница 3: ...er line on the display shows these values A manual selector switch is provided for memory selection in the Manual mode Controller Unit LED is lighted when Power Supply operates and Power Switch is off Power Switch L values switchable in 31 steps Never switch with full poser Max switching power 300W Control of the variable output capacitor 1 step corresponds to 0 9 tuning angel Max 200 steps Memory...

Страница 4: ... on the LC Display will be erased Cinch Connectors to loop in the key line of Power Amp RF Probe Installation Probe Connector to Controller AT 615 The connection to the Transceiver should made as short as possible To Power Amplifier RF Probe If possible the RF Probe should be attached directly to the antenna jack of the transceiver using an adaptor or a very short cable Page 4 of 24 ...

Страница 5: ...ance of the system is purely resistive when matched and is the ideal place for the Balun The regular station SWR meter or the built in meter in the TRX is used as an indicator to match the antenna The capacitors at front end are switched in 256 steps of 17 pF per step The capacitor at antenna side is a variable capacitor of 400 pF The control of this capacitor is by a stepper motor with 0 9 per st...

Страница 6: ...acing is 13 62 H x 9 41 W 346mm x 239mm Connect the ground bolt between the two antenna insulators with the lightning rod An application example If the RF Unit is installed outside a small roof or overhang is recommended to protect the unit from direct sun If the tuner is not protected the excessive temperatures inside the cabinet could damage the antenna tuner elements Page 6 of 24 ...

Страница 7: ...ck 1 Black Stepper Motor A 14 Blue Bwn 15VDC 2 Wht Blue Stepper Motor B 15 Grey Pink Stepper Mptor C 3 Red Stepper Mptor D 16 Wht Yel 36VDC 4 Blue GND 17 Wht Red Stepper End Position Sw 5 Pink 15VDC 18 Yel Bwn RFU C10 6 Pink Bwn RFU C9 19 Bwn Red L Ctl 2 6 MSB 7 Grey L Ctl 2 5 20 Blue Red L Ctl 2 4 8 Yellow L Ctl 2 3 21 Wht Grey L Ctl 2 2 9 Wht Pink L Ctl 2 1 LSB 22 Wht Grn Input C Ctl 2 8 MSB 10 ...

Страница 8: ...ency range of 1 8 to 30 MHz The antenna length is dictated by the space available rather than the usual resonant length It easily covers all amateur bands including WARC using a single wire dipole without traps Traps have long been known to induce losses and antenna s designed using them are frequently limited in overall bandwidth Some possible Installation Configurations ...

Страница 9: ...per side exhibit impedances that are very low These very low impedances can be difficult to match and some adjustments to lengths may be necessary Antennas are multiples of a half wave present very high impedances to the tuner and may result in internal arcing of the tuner elements If LAnt LFeeder is small in comparison to the wavelength i e 160m Amateur Radio band the internal tuner elements are ...

Страница 10: ... maximum by tuning the TRX and ANT controls so that the reflected power is minimum 4 Store the final values by pressing the momentary switch position Mem In Keeping the same values found switch to the next memory location 14030 30k set you transmitter to 14045 kHz center frequency Watch your SWR Meter if little or no change can be found store this value in memory If changes are necessary follow st...

Страница 11: ... 3575 14300 30k 14315 3590 30k 3605 14330 30k 14345 3620 30k 3635 3650 30k 3665 17m Band 3680 30k 3695 18060 40k 18080 3710 30k 3725 18100 40k 18120 3740 30k 3755 18140 40k 18160 3770 30k 3785 3800 40k 3820 15m Band 3840 40k 3860 21000 50k 21025 3880 40k 3900 21050 50k 21075 3920 40k 3940 21100 50k 21125 3960 40k 3980 21150 50k 21175 21200 50k 21225 60m Band US and UK only 21250 50k 21275 5320 40k...

Страница 12: ...corrections to bring the SWR to 1 1 use the ANT control knob only Never change L under full power condition When there is a sudden increase of the backward power while the amplifier power is increased most probably an arcing happened in the RF Unit Immediately switch of the transmitter The antenna is too short for this band frequency or it is resonant Example Values for a Matched Antenna Dipole 2 ...

Страница 13: ...e 24 x AWG22 0 35mm2 AMP plug Outdoor Cabinet Polycarbonate water tight UV resistant Dimensions L x W x H 14 x 10 2 x 6 5 inches Weight 6 kg 13 lbs Controller 3 rotary encoders are used to adjust tuner elements Tuning Memories 85 automatic or manual selectable Automatic Mode Frequency dependent selection of the memory locations Frequency is sensed by RF probe Displays LCD Display indicating single...

Страница 14: ... C L and output C Frequency Memory Location Standby LED LED while tuner is matching Power 15VDC 1 5A and 36VDC 0 5A Metal Bench Cabinet W x D x H 11 x 3 5 x 6 9 inches Weight 1 8 kg 4 lbs Power 15VDC 1 5A and 36VDC 0 5A Metal Bench Cabinet W x D x H 11 x 3 5 x 6 9 inches Weight 1 8 kg 4 lbs Page 14 of 24 ...

Страница 15: ......

Страница 16: ......

Отзывы: