DINTEK 6202-01001 Скачать руководство пользователя страница 33

Handheld Optical Power Meter

 

30

 

MAIN INDEX

 

Note

Frequency ID and wave ID cannot be operated at the same time. 

To avoid risk of serious eye damage, please do not look into the optical port of laser source at any time.

 

 

6.8  Power off  

Automatic power off

: When auto-off function is activated, the unit will turn itself off automatically after 

10minutes idle time, whatever the power supply is with alkaline batteries or is with power supply adaptor 
directly. 

Manual power off:

 Under any operation mode, hold down 

  for a few seconds to turn the unit off. 

 

Note

: With either power off operation, the unit will store the last calibration wavelength and backlight control mode 

automatically, which will be the default setting when user turns unit on next time.   

 

Chapter 7  Troubleshooting  

Problems 

Possible cause   

Solution 

Faint display on the LCD 

screen 

1.  Power is off 
2.  The battery power is 

too low 

1.  Press 

  key. 

2.  Change the batteries 

Inaccurate measurements 

1. Optical connector is not 
clean. 
2. incorrect fiber 

connection 

1.  Clean optical connectors 
2.  Re-connect the fiber   

Chapter 8    General Maintenance 

8.1    Always keep the connector ports of your power meter clean. 
8.2    Do not use bad quality optical fiber connectors/adaptors, otherwise, it will damage the interface of 
detector that will greatly affect the performance of the unit. 
8.3    Try to use only the adaptor supplied. 
8.4    Once not in use, make sure dust-proof cap is placed properly over the optical ports. 
8.5    Carefully plug in/out for fiber connectors/adapters to avoid scratches on the port of the power meter. 
8.6    Keep regular cleaning of optical port of power meter, please clean with cotton swabs supplied using 
alcohol properly. 

 

Содержание 6202-01001

Страница 1: ...Handheld Optical Power Meter MAIN INDEX DINTEK Handheld Power Meter Manual...

Страница 2: ...ds should have the possibility of returning WEEE at least free of charge Safety Advice 1 When the tester use Disposable alkaline batteries do not charge it Ensure the correct polarity installation whe...

Страница 3: ...14 5 3 Software function instruction 15 Chapter 6 Operation Instruction Notes 18 6 1 Powering the Optical Power Meter 18 6 2 Power on the optical Power Meter 19 6 3 Backlight setting 20 6 4 Output Po...

Страница 4: ...like automatic wavelength identification auto wavelength switching intelligent backlight and data saving via USB port Combined with DINTEK Handheld Optical Light Source it offers a quick and accurate...

Страница 5: ...ity 1000 Communication Port USB Standard Connector FC 2 5mm universal Optional Optical Connector FC SC ST Interchangeable 2 5mm universal Optional Optical Connector LC FC SC ST Interchangeable Alkalin...

Страница 6: ...ut off after 15 minutes idle time whatever the condition of battery power supply or AC power supply Once selecting this setting the auto off will display on the left bottom of the screen This power sa...

Страница 7: ...e intelligent backlight control mode Power meter will toggle off on the backside within 15 seconds based on the outside light condition LDR is the default backlight mode Back light control key mode Pr...

Страница 8: ...the record 2 Cancel the saving When in the saving mode press to cancel the current data saving 6 Unit switch key Press the Unit key to switch between the absolute measurement dBm and relative measurem...

Страница 9: ...dB absolute value dBm and Ref value relative value absolute value Ref 8 B L SET backlight indicator Indicate backlight control mode Green light indicates LDR intelligent backlight control mode Red li...

Страница 10: ...h the AC adaptor pic 4 4 4 4 4 5 2 Mini USB Port 1 Power Supply Unit AC adaptor Notice Please use only the power supply unit supplied with the tester Use of other kinds of PSU may cause damage to the...

Страница 11: ...e When changing the optical connector take care of the connector and the end face FC connector can connect with FC adaptor 2 5mm universal connector can connect with FC SC ST adaptor Pic 4 9 4 9 Notic...

Страница 12: ...strument information 2 Bracket Collapsible metal bracket 0 90 degree can be adjusted 3 Battery Pack This unit takes 3 x 1 5v AA batteries Notice When inserting the batteries take a note of their posit...

Страница 13: ...Double click that exe program This will initiate program See fig 5 1 5 1 Click INSTALL after you will see the following Fig 5 2 5 2 Press OK to exit this install interface However the driver still has...

Страница 14: ...n problems when the power meter is connected with the P open the Device Manager right click My computer choose property pop up the property interface choose hardware option click Device Manager find t...

Страница 15: ...INDEX Fig 5 6 Fig 5 7 After successful install of the device you can switch off the power meter and disconnect the USB cable 5 2 Install the application software Run the CD in the PC find the setup fi...

Страница 16: ...Handheld Optical Power Meter 13 MAIN INDEX Fig 5 8 Press Next as per Fig 5 9 Fig 5 9 Choose I accept Click Next as per Fig 5 10 Fig 5 10...

Страница 17: ...Handheld Optical Power Meter 14 MAIN INDEX Choose I accept click Next as per Fig 5 11 Fig 5 11 Click Next as per Fig 5 12 Fig 5 12 Fig 5 13...

Страница 18: ...on find the short cuts icon for this software Double click this icon to open the software You will see the software interface as per Fig 5 14 Data processing is the default interface once the software...

Страница 19: ...own the manual to choose V Save button save the current measurement data as the EXCEL file convenience for user to view and analysis the data on the PC VI Exit button disconnect the communication clos...

Страница 20: ...ta of the instrument 5 3 2 Power Meter setting Fig 5 15 Power Meter setting interface pic 5 3 2 which include 4 parts 1 Menu bar Please refer description in data process interface 2 Calibration the us...

Страница 21: ...electricity left 40 70 electricity left 30 40 electricity left 20 30 electricity not enough electricity left less than 20 the power meter will be forced to power off Fitting the batteries as per Fig...

Страница 22: ...me on the left top of the screen there will be a as per Fig 6 3 The tester will choose AC power supply as the default when batteries are also installed Fig 6 3 When using the AC adaptor connect the po...

Страница 23: ...er long press to choose the backlight control mode 6 3 1 LDR Intelligent backlight control mode Long press B L SET is green 6 6 after 10 seconds the green LED indicates off the LDR the controller will...

Страница 24: ...cord is connected 6 4 2 Select the wavelength Short press select the calibrated wavelength notice that if the selected wavelength is not the same as the laser source wavelength it will cause an error...

Страница 25: ...g memory of 1000 records After completing the output power measurement press at the right top of the screen which will display the data saving No eg 0008 see fig 6 11 Hint Double press to confirm the...

Страница 26: ...ails of installation please refer to chapter 5 6 5 1 Opening the software Double click the icon to open the software The user can choose the language on request Chinese or English as shown in figure 6...

Страница 27: ...will pop up a successful connection window shown as 6 17 click OK to finish the connection the unit will now be communicating with the PC Fig 6 16 Fig 6 17 6 5 2 Data edit Firstly input the following...

Страница 28: ...e data display area including data delete data save and data printing Select the required data click delete one to delete it from the sheet as shown on figure 6 20 and figure 6 21 in addition The corr...

Страница 29: ...igure 6 22 click OK to delete all data also will clear all saved data from the unit 6 22 Click Save pop up a window shown in figure 6 23 input the file name choose the save path and press ok for stora...

Страница 30: ...report directly you can also print the testing report from Excel 6 5 3 Function setting on the unit Under the function setting mode you can switch the interface as shown on figure 6 25 and figure 6 26...

Страница 31: ...D operation mode press of light source to emerge light output from light source Hold down for few seconds light source will enter into Wave ID mode also AU will be shown on the upper right of LCD for...

Страница 32: ...on Power Meter Connect power meter with its same serials light source JW3116 Output frequency from MATCHED optical light source Press to emerge light from the unit press for very short second MATCHED...

Страница 33: ...ext time Chapter 7 Troubleshooting Problems Possible cause Solution Faint display on the LCD screen 1 Power is off 2 The battery power is too low 1 Press key 2 Change the batteries Inaccurate measurem...

Страница 34: ...arranty is limited to defects in workmanship and materials and does not cover damages from accident acts of god neglect wrong usage or abnormal conditions of operation 4 The company will charge corres...

Отзывы: