DAG Series FXO Voice Gateway User Manual
26
Dinstar Technologies Co., Ltd.
Call Progress Tone:
Hear the dial tone when pick up the phone. Choose the
national standards from the drop-down box. Default is the United States.
Timeout for Dialing
: With the help of dialing timeout, you can limit the time while
users typing the digits from an extension. If the timeout expire while the user is
typing in the extension then DAG will consider the extension as complete and it will
try to send to SIP server. Default value is 4 seconds.
Timeout for Answer (Outgoing Call):
This timer set how long the caller party
waiting when makes outgoing call on extension.
Timeout for answer (Incoming call):
This timer set how long the phone sets
ringing when get incoming call.
No RTP Detect:
This option is to disconnect call when there is no RTP received.
Default value is 90s
Incoming call setting and Caller ID
Configuration by FXO:
When the call from FXO interface, users can be enable or disabled FXO allocation
function. FXO configuration function includes: detect CID, Send original CID, Play hint to