30
Error and protection conditions
I
2
HOT
START
ARC
FORCE
PULSE
CYCLE
T
b
f
T
p
I
1
I
p
I
b
PULSE
SYN
FAST
SLOW
WAVE
VRD
CYCLE
Ø
PULSE
SYN
FAST
SLOW
WAVE
D
The equipment is protected against problems and if any arise the
DISPLAY shows fixed or flashing (error code) messages (depend-
ing on the type of error) that serve to inform the operator that a fault
has occurred in the equipment (see table 1).
The table provides a summary of all the error conditions that may
arise on the equipment and, if possible, what the operator must
do to attempt to resolve the problem.
Automatic reset error:
once the alarm condition has been re-
solved the equipment starts working again and the operator can
weld again!
PLEASE NOTE: If the fault persists look for the cause of the
fault and contact our technical assistance department if nec-
essary.
All of this is necessary to allow our technical assistance depart-
ment to resolve problems more easily, as quickly as possible and
thanks to the user’s reports, also because, in the meantime the
welding power source will not allow the operator to do their work.
Table 1
Display
Diagnosis
E01
PRESSURE SWITCH
This message appears when the cooling equipment
is connected to the welding power source and its
pressure switch does not close due to a lack of
pressure in the hydraulic circuit.
Automatic reset error.
E02
OVER VOLTAGE
This message appears when the power supply
voltage for the DIX TIG 2506.M AC/DC exceeds
500V
.
If the fault persists look for the cause of the fault
and contact our technical assistance department if
necessary.
Automatic reset error.
E03
UNDER VOLTAGE
This message appears when the power supply
voltage for the DIX TIG 2506.M AC/DC drops below
280V
.
If the fault persists look for the cause of the fault
and contact our technical assistance department if
necessary.
Automatic reset error.
t°C
THERMAL PROTECTION
The welding stops due to an excessively high
temperature (thermostat activated).
Automatic reset error.
WARNING: The DIX TIG 1806.M AC/DC welding power source
has a built-in electronic protective device to deal with fluctua-
tions in mains voltage that switches the welding power source
off automatically (voltage exceeding 300 V), without indicat-
ing any type of error or warning message for the operator.
Subsequently it starts functioning again automatically when
the voltage has dropped to below the value indicated above.