DINSEO DIX TIG GO 1806.M AC/DC Скачать руководство пользователя страница 20

20

5B) 

BALANCING the AMPLITUDE of the CURRENT (I) 

(-50÷+20)

 

It is possible to adjust the amplitude of the current (I) while the 
electrode stays in place independently, using positive or neg-
ative values, guaranteeing perfect control of penetration and 
cleanliness, drastically reducing side incisions.

Display

-

+

-50

150%

50%

I

 (A)

t

 (s)

Display

-

+

0

100%

100%

I

 (A)

t

 (s)

Display

-

+

+20

80%

120%

I

 (A)

t

 (s)

 

Press the BALANCING and FREQUENCY (T4) key once, wait 
a few seconds, and hold the same key down for at least 

2

 sec-

onds. Then use the ENCODER Knob (E) to adjust the value 
shown on the DISPLAY (D).

I

1

PULSE

SYN

FAST

SLOW

WAVE

Ø

DIX TIG GO

1806.M

I

1

SYN
FAST
SLOW

VRD

HF

AC

DC

DC

HF

HOT

START

ARC

FORCE

I

b

T

b

T

p

f

I

p

I

2

MEM

PRG

PULSE

PULSE

ULTRA

FAST

WAVE

WAVE

A
V

SWITCH

SWITCH

D

T4

E

LED 

 L30 

 flashing intermittently.

 

To exit, simply push the BALANCING and FREQUENCY (T4) 
key again (BALANCING LED off).

5C) 

BALANCING  (BALANCE PLUS) 

 

It is possible to adjust the time (t) and amplitude of the cur-
rent (I) while the electrode stays in place simultaneously and 
independently, using positive or negative values, guarantee-
ing perfect control of penetration and cleanliness, drastically 
reducing side incisions.

 

For simultaneous setting of the parameters, following the in-
structions given in points 5A and 5B in succession, with the 
help (if necessary) of the example shown below.

Display

-

+

t -15

65%

35%

I -20

120%

80%

I

 (A)

t

 (s)

6) 

FREQUENCY CONTROL IN AC

 (40 ÷ 250 Hz)

 

This controls the frequency for the various wave shapes, for 
better directional control, reducing the thermally altered area, 
with greater penetration and lower electrode consumption. 
The high frequency makes it possible to weld very small thick-
nesses with excellent results, while the low frequency is ideal 
for welding average thicknesses, or where edge preparation 
is poor.

I

 (A)

t

 (s)

I

 (A)

MIN 40 Hz

MAX 250 Hz

t

 (s)

 

To regulate the FREQUENCY push the BALANCING and 
FREQUENCY key (T4) twice (FREQUENCY LED flashing) 
and use the ENCODER Knob (E) to regulate the value indi-
cated on the DISPLAY (D).

I

1

PULSE

SYN

FAST

SLOW

WAVE

Ø

DIX TIG GO

1806.M

I

1

SYN
FAST
SLOW

VRD

HF

AC

DC

DC

HF

HOT

START

ARC

FORCE

I

b

T

b

T

p

f

I

p

I

2

MEM

PRG

PULSE

PULSE

ULTRA

FAST

WAVE

WAVE

A
V

SWITCH

SWITCH

T4

E

D

 

To exit, simply push the BALANCING and FREQUENCY (T4) 
key again (FREQUENCY LED off).  

7)  Press the WELDING MODE SELECTION Key (T9) and go to 

one of the 

4

 options available:

 

 L5 

 2T

 

 L6 

 4T

 

 L7 

 SWITCH

 

 L8 

 SPOT WELD

8)  By pushing the WELDING PARAMETERS SE-

LECTION key a number of times it is possible to 
set the various TIG WELDING PARAMETERS 
(see the “TIG AC and DC Welding” paragraph - 
WELDING PARAMETERS).

9)  Once the all the selections/regulations indicated 

above have been made, welding can begin.

10)  During the welding process the DISPLAY shows the real Amps 

(A) at which the operator is actually welding.

T9

L5

L6

L7

L8

SWITCH

Содержание DIX TIG GO 1806.M AC/DC

Страница 1: ...ing Power Source S C H W E I S S E N W E L D I N G W E L D I N G S C H W E I S S E N S C H W E I S S E N Keep in secure area for future reference Operations manual DIX TIG GO 1806 M AC DC DIX TIG GO 2...

Страница 2: ...lding machines are Innovative and compact design Compact size and light weight for easy transportation Metallic main structure with shock proof plastic front panel Protective visor on the control pane...

Страница 3: ...ent in complete safety for a period of work of X of the total us age time The regulations in force establish the total usage time to be 10 minutes The work cycle is considered to be X of this period o...

Страница 4: ...ertures made in the frame The welding unit is characterised by the following levels Protection level IP 23 S indicates that the equipment can be used both indoors and outdoors Use class S means that t...

Страница 5: ...le Cutting robot or for automatic equipment Connect the cable to the analogue digital interface as shown in figure Pos 2 Fig B To connect the other end of this cable see the diagram in the man ualfor...

Страница 6: ...ut the electrode at the point at which welding is to begin put the TIG torch at an angle so that the edge of the gas nozzle is not on top of the piece to be welded keeping contact be tween the point o...

Страница 7: ...ic emission Much attention must be afforded so that the ground connection of the part to be welded does not increase the risk of accident to the user or the risk of dam age to other electric equipment...

Страница 8: ...an emp ty programme between saved ones NOTE The value shown on the display during welding represents the effective current output with all types of control The digital control unit of the welding pow...

Страница 9: ...th increased risk of electroshock Product suitable for free circulation in the European Community Danger High voltage Grounding Positive pole snap in connector Negative pole snap in connector Connecto...

Страница 10: ...10 Wiring diagram DIX TIG GO 1806 M AC DC...

Страница 11: ...11 2101WA31...

Страница 12: ...12 Wiring diagram DIX TIG GO 2506 M AC DC...

Страница 13: ...13 2101WB09...

Страница 14: ...tal interface PCB 31 Inverter PCB 32 Automation interface isolation board optional extra 33 Secondary circuit diodes PCB 34 Secondary circuit PCB 35 EMC filter PCB 36 High frequency HF PCB 37 Secondar...

Страница 15: ...L4 DIX TIG GO 1806 M I1 SYN FAST SLOW VRD HF AC DC DC HF HOT START ARC FORCE Ib Tb Tp f Ip I2 MEM PRG PULSE PULSE ULTRA FAST WAVE WAVE A V A V SWITCH SWITCH WELDING PARAMETERS ENCODER knob DISPLAY VR...

Страница 16: ...on is divided into 3 types TIG AC and TIG LIFT DC tack welding TIG HF DC tack welding with a single DIX ARC COOL SPOT point TIG HF DC tack welding with a Multi DIX ARC COOL SPOT function See the relev...

Страница 17: ...rce is activated this allows you to select the follow ing welding parameters based on which LED is flashing L12 PRE GAS duration L13 SLOPE UP duration L14 BASE current duration Tb WARNING This can onl...

Страница 18: ...set at the start of the welding process thereby reducing the risk of poor fu sion at the start of the joint L9 HOT START 00 100 MMA ARC FORCE Regulates in percentage terms the dynamic characteristics...

Страница 19: ...deal for minor thicknesses WARNING LED L25 switched on and flashing The display shows the RMS current value for pre set ting and welding 1806 M AC DC 2506 M AC DC TIG AC COLD TIG 16 127 A 5 173 A I A...

Страница 20: ...essary of the example shown below Display t 15 65 35 I 20 120 80 I A t s 6 FREQUENCY CONTROL IN AC 40 250 Hz This controls the frequency for the various wave shapes for better directional control redu...

Страница 21: ...S SELECTION T10 key a number of times it is possible to set the various TIG WELDING PARAMETERS see the TIG AC and DC Weld ing paragraph WELDING PARAMETERS 7 Once the all the selections regulations ind...

Страница 22: ...ctually welding T5 Multi spot welding with Multi DIX ARC COOL SPOT function with TIG HF DC welding The Multi DIX ARC COOL SPOT function can be used for cold tacking in quick succession to further exte...

Страница 23: ...STROKES or SWITCH welding mode is activated L13 SLOPE UP duration 0 0 5 0 sec L11 PRINCIPAL welding CURRENT I1 1806 M AC DC 2506 M AC DC TIG DC 5 220 A 5 300 A TIG AC DYNAMIC TIG SPEED TIG COLD TIG SO...

Страница 24: ...T Ib 1806 M AC DC 2506 M AC DC 5 220 A 5 300 A L21 PEAK CURRENT Ip 1806 M AC DC 2506 M AC DC 5 220 A 5 300 A PULSE SYN FAST SLOW T5 L23 PULSATION FREQUENCY f 1806 M AC DC 2506 M AC DC FAST 0 5 500 Hz...

Страница 25: ...pulsation is active SLOW LED on Press the WELDING MODE SELECTION key T9 until the SWITCH welding mode is active SWITCH LED on Press the WELDING PARAMETERS SELEC TION Key T10 a number of times to set t...

Страница 26: ...ARAM ETERS defined as being BASIC L11 L19 L22 T10 L11 L21 1st LEVEL PEAK CURRENT I1p 1806 M AC DC 2506 M AC DC 25 220 A 25 300 A WARNING When the SYN PULSE function is active the 1st level PEAK CURREN...

Страница 27: ...be programmed when the TIG AC with HF ignition or TIG DC with HF ignition welding processes and the 2 STROKES welding mode are used To exit the setting phase hold the WELDING PARAMETERS SE LECTION ke...

Страница 28: ...e set values as they cannot edit any type of parameter function To edit switch to MANUAL welding mode MANUAL WELDING To go back to set edit the parameters selected or to create a new program proceed a...

Страница 29: ...nd prevents welding During welding the VRD LED turns RED which does not indicate any malfunction on the welding power source but that the VRD device has been deactivated to allow welding T10 Auxiliary...

Страница 30: ...Display Diagnosis E01 PRESSURE SWITCH This message appears when the cooling equipment is connected to the welding power source and its pressure switch does not close due to a lack of pressure in the...

Отзывы: