background image

DIX GO 1206.M

BA-0110

Welding Power Source

S C H W E I S S E N

W E L D I N G

W E L D I N G

S C H W E I S S E N

S C H W E I S S E N

Keep in secure area for future reference!

Operations manual

Содержание DIX GO 1206.M

Страница 1: ...DIX GO 1206 M BA 0110 Welding Power Source S C H W E I S S E N W E L D I N G W E L D I N G S C H W E I S S E N S C H W E I S S E N Keep in secure area for future reference Operations manual...

Страница 2: ...w electrical input from the main supply by the welder Extremely high frequency power INVERTER with very latest type of IGBT to reduce switching losses to a minimum The inverter resists ample current v...

Страница 3: ...th the producer s instructions contained in this manual Before installing the system the user must take into consideration the potential electromagnetic problems in the work area In particu lar we sug...

Страница 4: ...Fig A to the ELECTRODE position for welding using basic electrodes with an Arc Force and Hot Start device or Cr Ni ELECTRODE for welding stainless steel with special characteristics to achieve a soft...

Страница 5: ...on nector marked negative 2 Adjust the welding current using the potentiometer Pos 2 Fig A 3 Turn the process selector Pos 3 Fig A to the TIG position 4 Start the welding machine by selecting Pos 1 on...

Страница 6: ...tions that are the cause of overheating The pointing out of any difficulties and their elimination The supply line is attributed with the cause of the most common difficulties In the case of breakdown...

Страница 7: ...7 2101F634 IT Schema elettrico EN Wiring diagram FR Sch ma lectrique DE Schaltplan ES Esquema el ctrico NL Elektrisk skema PT Esquema el ctrico...

Страница 8: ...l 3 Doubler card 4 INVERTER power card 5 INVERTER control card 6 Supply switch 7 DIX GO 1206 M Green POWER SUPPLY LED 8 Yellow LED for overheat cutofft 9 Blower 10 Current potentiometer 11 Primary rec...

Страница 9: ...increased risk of electroshock 7 Danger high voltage 8 Grounding protection 9 Grounding 10 Positive pole snap in connector 11 Negative pole snap in connector 12 Warning 13 Before using the equipment...

Страница 10: ...1 Forced air cooling 12 Insulation class 13 Supply voltage 14 Maximum value of rated supply current 15 Degree of protection of casing 16 Product suitable for free circulation in the European Community...

Страница 11: ...INVERTER control card RT1 Adjustment of the maximum current RT2 Adjustment of the minimum current RT4 Hot Start adjustment RT5 Adjustment of the striking current in TIG welding with the Lift ignition...

Отзывы: