4.Clean out any debris and examine the valve housing
and seat. If the seat is damaged, reverse or replace
the seat.
5..Remove, clean, and inspect the upper cage and
upper ball. Replace if they are worn or damaged.
6.Reassemble the valves by reversing the steps
above.

Repacking the Fluid Section

NOTE:The factory-installed packings are black in
color. The replacement packings in the packing
replacement kit are white.

1.Remove the foot valve and outlet valve assemblies
using the steps in the ¡°Servicing the V alves¡±
procedure above.
2.Using 3/8¡± a hex wrench, loosen and remove the
two pump block mounting screws.
3.Pull the pump block down approximately 1/2¡±
from the pump housing.
4.Slide the pump block and piston rod forward until
the piston rod is out of the T-slot on the connecting
rod.
5.Slide the piston rod out through the bottom of the
pump block
6.Loosen and remove the retainer nut and piston
guide from the pump block.
7.Remove the upper and lower packings from the
pump block.
8.Clean the pump block and install the new upper and
lower packings. Refer to the illustration below for
proper packing orientation.
9.Inspect the piston rod for wear and replace if
necessary.
10.Reassemble the outlet valve assembly into the
piston rod. Tighten the outlet valve housing with a
wrench until secure.

NOTE: Use the T-slot on the connecting rod to
hold the piston rod in position while securing the
outlet valve housing.

Never use a wrench on the piston itself. This could
cause damage to the piston and cause leakage.
11. Insert the piston guide into the retainer nut.
Thread the retainer nut into the pump block until it is
hand tight.
12.Slide the piston guide tool (included in the
repacking kit) over the top of the piston rod and insert
the piston rod through the bottom of the pump block.
Using a rubber mallet, tap the bottom of the piston rod
lightly until the piston rod is in position in the pump
block.

NOTE:Coat the piston guide tool and the piston
rod with grease before inserting them into the
pump block.

13.Using a wrench, tighten the retainer nut securely.
14.Slide the top of the piston rod into the T-slot on the
connecting rod.
15.Position the pump block underneath the pump
housing and push up until it rests against the pump
housing.

Make sure the transducer is aligned properly with
the hole in the pump block during reassembly.
Improper alignment may cause damage to the
transducer gasket.

16.Thread the pump block mounting screws through
the pump block and into the pump housing. Tighten
securely.
17.Reassemble the foot valve assembly into the pump
block.
18.Insert the elbow on the suction set into the bottom
of the foot valve. Position the retaining clip into the
foot valve to secure the suction set assembly.
19.Thread the return hose into the pump block and
tighten securely.
20.Place the front cover on the pump housing and
secure in position using the four front cover screws.
21.Turn on the sprayer by following the procedure in
the ¡°Operation¡± section of this manual and check for
leaks.

NOTE:Repacking kit is available. For
best results use all parts supplied in this kit.

12

Содержание DP-6336iB

Страница 1: ...ully before attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Retain instruction for future reference www dpairless com www dino power com www airlesspaintsprayer pump com 1 ...

Страница 2: ...nd in front of the gun Gloves will not provide protection against an injection injury ALWAYS lock gun trigger shut pump off and release all pressure before servicing cleaning tip or guard changing tip or leaving unattended Pressure will not be released by turning off the motor The PRIME SPRAY valve handle must be turned to PRIME to relieve the pressure Refer to the PRESSURE RELIEF PRESSURE describ...

Страница 3: ... spraying flammable materials 12 Use lowest possible pressure to flush equipment Earthing Instructions This product must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This product is equipped with a cord having a grounding wire with an appropriate grounding plug The plug must be plugged into...

Страница 4: ...onds without fluid Operating this unit without fluid will cause unnecessary wear to the packings 7 Make sure the electrical service is 220V 50HZ 8 Plug the power cord into a properly grounded outlet at least 25 from the spray area Always use a minimum 12 gauge three wire extension cord with a grounded plug Never remove the third prong or use an adapter Preparing a New Sprayer If this unit is new i...

Страница 5: ...re to do so may lead to a static electric discharge which may cause a fire 11 Trigger the gun into the metal waste container until the old solvent is gone and fresh solvent is coming out of the gun 12 Lock the gun by turning the gun trigger lock to the locked position 13 Set down the gun and increase the pressure by turning the pressure control knob slowly clockwise 14 Check the entire system for ...

Страница 6: ...re control knob counter clockwise to its OFF position 4 Unlock the gun by turning the gun trigger lock to the unlocked position 5 Hold the metal part of the gun firmly to the side of a metal container to ground the gun and avoid a build up of static electricity 6 Trigger the gun to remove any pressure that may still be in the hose 7 Lock the gun by turning the gun trigger lock to the locked positi...

Страница 7: ...mely helpful in these situations Nearby objects such as automobiles outdoor furniture etc should be moved or covered whenever in the vicinity of a spray job Be careful of any other surrounding objects that could be damaged by overspray Practice 1 Be sure that the paint hose is free of kinks and clear of objects with sharp cutting edges 2 Turn the pressure control knob counterclockwise to its to it...

Страница 8: ...e return hose into the metal waste container 9 Turn the unit off by moving the ON OFF switch to the OFF position 10 Move the PRIME SPRAY valve up to its SPRAY position 11 Turn the unit on Ground the gun by holding it against the edge of the metal container while flushing Failure to do so may lead to a static electric discharge which may cause a fire 12 Trigger the gun into the metal waste containe...

Страница 9: ...4 Remove the capacitors from their mounting clip 5 Loosen and remove the four motor mounting screws 6 Pull the motor out of the pump housing NOTE If the motor will not dislodge from the pump housing Remove the front cover plate Using a rubber mallet carefully tap on the front of the motor crankshaft that extends through the connecting rod 7 With the motor removed inspect the gears in the pump hous...

Страница 10: ...loosen and remove the two pump block mounting screws 5 Pull the pump block down approximately 1 2 from the pump housing to clear the transducer 6 Slide the pump block and piston rod forward until the piston rod is out of the T slot on the connecting rod 7 Loosen and remove the four electronic pressure control EPC mounting screws 8 Pull back the EPC for access to the transducer 9 Unplug the transdu...

Страница 11: ...ock Always unplug the sprayer before servicing 3 Unscrew the return hose assembly from the pump block 4 Remove the retaining clip that holds the suction set in the foot valve Pull the suction set out of the foot valve 5 Tilt the pump back for easy access to the fluid section Servicing the Valves The design of Titan s fluid section allows access to the foot valve and seat as well as the outlet valv...

Страница 12: ...n itself This could cause damage to the piston and cause leakage 11 Insert the piston guide into the retainer nut Thread the retainer nut into the pump block until it is hand tight 12 Slide the piston guide tool included in the repacking kit over the top of the piston rod and insert the piston rod through the bottom of the pump block Using a rubber mallet tap the bottom of the piston rod lightly u...

Страница 13: ... the new or cleaned filter into the gun body 5 Make sure the handle seal is in position and thread the handle into the gun body until secure 6 Move the gun trigger lock to the locked position NOTE Left handed threads require turning the filter clockwise to remove NOTE For more detail part number information and assembly drawings at larger scale please see the Professional Airless Gun Owner s Manua...

Страница 14: ...d 14 ...

Страница 15: ...er cage 13 Outlet valve ball 14 Outlet valve seat 15 O ring 16 Outlet valve retainer 17 Bushing 18 Lower seal 19 Lower cage 20 Foot valve ball 21 Foot valve seat 22 O ring Item Description 23 Foot valve housing 24 Seal 25 Filter 26 Filter housing 27 PRIME SPRAY valve assembly includes items 28 38 28 Gasket 29 O Ring Viton 30 O Ring Teflon 31 Valve housing 32 O Ring Viton O Ring Teflon optional 33 ...

Страница 16: ...16 ...

Страница 17: ...17 ...

Отзывы: